en-us Conversion to LP gas
Adjust the black T10 star head setting screw with a T10
6.
star head screwdriver. Refer to the burner chart for the
correct setting of the setting screws (M).
→ "Burner chart", Page 16
Use setting
for LP Gas. The setting screws must
‒
be tightened properly.
Use setting
for natural gas. The setting screws
‒
must finish flush with the fitting.
The dual-flame burner has 2 setting screws.
Replace the black disks.
7.
Replace the electronics pack applying light pressure so
8.
the tabs engage. Make sure not to pinch any connecting
cables.
Ensure that the gaskets around the burner bases are in
9.
place.
5.4 Burner chart
Refer to this overview for specifications of the individual burners.
Burner
Gas type
cap
Small
Natural gas
burner
Propane gas
Large
Natural gas
burner
Propane gas
Medium
Natural gas
burner
Propane gas
16
Pressure
Orifice
in inch
wc
6
77
10
54
6
133
10
93
6
102
10
71
Reinstall the main top and the control knobs.
10.
Replace all burner bases, burner caps and burner
11.
grates.
Continue the installation procedure from
12.
→ "Connection overview", Page 11
When the installation is complete, verify that the
13.
appliance works properly.
→ "Checking the installation", Page 12 .
Note: In the event of damage, the valve must be
completely replaced.
BTU/h
kW
3,400
1.00
3,400
1.00
10,300
3.00
10,300
3.00
6,000
1.75
6,000
1.75
M (valve
adjustment
screw setting)