7.4.1 PRO 2
Room thermostat for rear fan control (PRO 2)
It is possible to connect a room thermostat to
the terminal board of the stove so that the rear
fan can be switched on and off according to the
temperature set on the thermostat.
To use this function, rear fan ventilation must be
64
C
A
T
A
B
Fig. 26
22.15 20.3 °C
6
22.15 20.3 °C
1
T
6
5
4
3
2
1
Fig. 27
set to ON.
The thermostat that controls the rear fan must
be connected to terminals 5 and 6 of the terminal
board in place of the bridge.
7.5
Electrical connection
Simply connect the appliance to the electrical
system using the supplied plug (Fig. 28).
The electrical connection (plug) must be easily
accessible after appliance installation as well.
If the power supply cable is damaged
it must be replaced by the technical
assistance service or a qualified techni-
cian in order to prevent any risk.
The system must be equipped with
an earth connection and a differential
switch in compliance with the laws in
force.
The flue gas evacuation duct must
be equipped with its own earth
connection.
7.6
Fuel optimisation
Excellent fuel depends on different factors (type
of installation, operating and maintenance con-
ditions, type of pellets, etc.)
Upon first ignition, the stove can be regulated for
optimum combustion performance.
Generally speaking, if at the end of combustion,
there is a lot of residue in the burn pot, you
should change the combustion configuration
(by increasing the value) until you find the best
solution.
Refer to function "(14) Combustion" of the use
and functionality manual.