7.2.2 Single-wall pipe and air intake in room
In this case the combustion air will be taken from
the room.
To achieve this:
• Insert the aesthetic ring support (A) and the
ring (B) (supplied with and placed inside the
combustion chamber during transport).
• Connect the flue gas outlet pipe (C) (Fig. 22).
A
62
7.2.3 Single wall pipe and outside air intake
In this case the combustion air is taken directly
from outside, from the back of the stove.
• Remove the back panel of the stove (A)
• Disconnect the flexible combustion air hose (B)
at the top and bottom.
• Insert the aesthetic ring support (C) and the
ring (D) (supplied with and placed inside
the combustion chamber during transport)
(Fig. 23)
C
B
Fig. 22
B
C
A
004778882 - 28/09/2023
D
B
Fig. 23