Télécharger Imprimer la page

Parkside 46876 Instructions D'utilisation Et Consignes De Sécurité page 28

Publicité

9. Transport
• Tighten the set screw (26) in order to lock the rotary
table (14)
• Activate the release lever (3), press the machine
head (4) downwards and secure with the safety pin
(23). The saw is now locked in its bottom position.
• Fix the saw's drag function with the locking screw for
drag guide (20) in rear position.
• Carry the equipment by the fixed saw table (15).
• When reassembling the equipment proceed as de-
scribed under section 7.1.
10. Maintenance
m Warning! Prior to any adjustment, maintenance or
service work disconnect the mains power plug!
General maintenance measures
Wipe chips and dust off the machine from time to time
using a cloth. In order to extend the service life of the
tool, oil the rotary parts once monthly. Do not oil the
motor.
When cleaning the plastic do not use corrosive prod-
ucts.
Brush inspection
Check the carbon brushes after the first 50 operating
hours with a new machine, or when new brushes have
been fitted. After carrying out the first check, repeat the
check every 10 operating hours.
If the carbon is worn to a length of 6 mm, or if the spring
or contact wire are burned or damaged, it is necessary
to replace both brushes. If the brushes are found to be
usable following removal, it is possible to reinstall them.
11. Storage
Store the device and its accessories in a dark, dry and
frost-proof place that is inaccessible to children. The
optimum storage temperature is between 5 and 30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from dust
and moisture.
Store the operating manual with the electrical tool.
12. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customer's mains connection as well as the
extension cable used must also comply with these
regulations.
• The product meets the requirements of
EN 61000-3-11 and is subject to special connec-
tion conditions. This means that use of the product
at any freely selectable connection point is not al-
lowed.
• Given unfavorable conditions in the power supply
All manuals and user guides at all-guides.com
the product can cause the voltage to fluctuate tem-
porarily.
• The product is exclusively intended for use at con-
nection points that have a continuous current-carry-
ing capacity of at least 100 A per phase.
• As the user, you are required to ensure, in consulta-
tion with your electric power company if necessary,
that the connection point at which you wish to oper-
ate the product meets the specified requirements.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the mo-
tor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H05VV-F".
The printing of the type designation on the connection
cable is mandatory.
AC motor
• The mains voltage must be 230 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm2.
Connections and repairs of electrical equipment
may only be carried out by an electrician.
Please provide the following information in the event of
any enquiries:
• Type of current for the motor
• Machine data - type plate
• Machine data - type plate
13. Disposal and recycling
The equipment is supplied in packaging to prevent it
from being damaged in transit. The raw materials in
this packaging can be reused or recycled. The equip-
ment and its accessories are made of various types of
material, such as metal and plastic. Defective compo-
nents must be disposed of as special waste. Ask your
dealer or your local council.
GB
23

Publicité

loading

Ce manuel est également adapté pour:

Pzks 1500 a1