EN
A
PICTURES
[1] 1 AC Motor Controller WM 100-240 V AC,
wall mounted version
[2] 1 AC Motor Controller PCB 100-240 V AC,
PCB version (with DIN rail clip, Ref. 9008049)
B
MOUNTING
Choose the optimal location: flat and large surface,
open the housing.
[1] Mount the 1 AC Motor Controller WM
[2] Mount the DIN rail version
1.
Vertical (wall mounted or PCB version)
2.
Horizontal (wall mounted version)
C
WIRING
[1] Connect power supply and wiring to the
Motor Controller
[2] Insulated screwdriver
[3] Wiring diagram
[4] Check the correct running directions of the end product
UP: the end product goes up ( C + s)
STOP: the end product stops ( C + t + s)
DOWN: the end product goes down ( C + t)
n To close window press UP,
to open window press DOWN.
[5] Possible switches
1.
Inteo Centralis IB, Ref. 1810138
2.
Double push button
D
CONFIGURATION
[1] Reset / Prog button
With this button, you can access the basic configu-
ration of the Motor Controller.
1.
Wall mounted version
2.
PCB version
CABLE
Connection to ...
Motors
Switch
Group control
100-240 V AC
Cables
Min.: 4 x 0.75 mm
/18 AWG
2
Max.: 4 x 2.5 mm
/14 AWG
2
Min.: 3 x 0.6 mm/22 AWG
Max.: 3 x 2.5 mm
/14 AWG
2
Min.: 4 x 0.6 mm/22 AWG
Max.: 4 x 1.5 mm
/16 AWG
2
Min.: 3 x 1.5 mm
/16 AWG
2
Max.: 3 x 2.5 mm
/13 AWG
2
[2] Selection of switch ergonomic
Local push button ergonomics and the type of end
products to be preselected:
• Screen mode
• Venetian blind, European mode (default mode)
• Venetian blind, US mode
1.
To toggle between modes, press the Reset / Prog
button 2 s. Repeat until the LED, according to
the desired configuration, lights up. Store by
pressing 2 s.
[3] Factory RESET
[4] Learn running time/length
1.
Drive screen to upper end limit
2.
Press Stop until screen drives down on its own
3.
Press Stop when lower end limit is reached
[5] Symbols: actions
1.
Up
2.
Stop
3.
Down
[6] Symbols: end product status
1.
Up
2.
Upper end position
3.
Down
4.
Lower end position
m When electronic motors are to be controlled through this
Motor Controller device it is mandatory to configure the start-
up delay time for electronic motors in the Motor Controller
settings. To configure the start-up delay time WT Setting Tool
Ref. 1811242 can be used.
Twisted pairs
-
Recommended
Recommended
-
animeo IB+ 1 AC MOTOR CONTROLLER. REF. 5047280 D -
Max. distance
150 m
100 m
1000 m
8/16