Problem
The vacuum cleaner
does not start when it is
switched on.
The operating noise is
changing during vacu-
uming.
The Electrobrush
switches itself off.
The vacuum cleaner
keeps falling over.
Possible cause and solution
There is no battery inserted or the battery is inserted
incorrectly.
 Insert the battery or check how the battery is posi-
tioned (see "Installation and connection" – "Insert-
ing the battery").
The rechargeable battery is not sufficiently charged.
 Charge the battery exactly as described in these
operating instructions (see "Installation and con-
nection" – "General battery information" and
"Charging the battery").
An original Miele battery has not been inserted.
 Insert an original Miele AP01/AP02/AP03 lithium-
ion rechargeable battery (HX LA).
The battery was not placed in the PowerUnit when
charging it for the first time.
 To activate the battery, it must be placed in the
PowerUnit the first time it is charged (see "Instal-
lation and connection" – "General battery informa-
tion" and "Charging the battery").
The charger is still plugged in.
 Pull the plug out of the charging socket on the bot-
tom of the battery.
The Electrobrush power consumption is automatically
set to the optimum level based on the type of flooring
and roller brush used.
 The noise is not unusual – the vacuum cleaner is
functioning normally.
The Electrobrush is overloaded – this can happen on
surfaces like deep-pile carpet.
 Switch the vacuum cleaner off and switch it on
again at a reduced suction power level. Use the
On/Off switch on the Comfort handle to do this.
You have configured the vacuum cleaner with the
PowerUnit at the top.
 Reassemble the vacuum cleaner so that it is con-
figured with the PowerUnit at the bottom (see "In-
stallation and connection" – "Assembling the vac-
uum cleaner").