- What to do if...? ... Check.

What to do if...?

- No synchronisation after
installation
No DHCP server on the
network
1) Check that the signal type sent by the master clock is the same
as the clock's signal type (IE NTP).
2) Check that the IP address of the server is identical on the
clock's web interface and the receiver.
3) The NTP server is on the same network as the receiver (IP
address, subnet mask and gateways).
1) By default the interface takes on the following IP setting
(after 3min):
- IP: 192.192.223.100
- MASK: 255.255.0.0
- Gateway: 0.0.0.0
- DNS: 0.0.0.0
(After 15 minutes, the interface asks an address DHCP
server).
2) Use soft « BODET Detect « PC with the button « Network
configuration « to define the network parameters of the clock.