ASSEMBLY INSTRUCTIONS (CONT)
4. When the desired location is determined, measure 33" / 838 mm up from the floor and mark
the location. This location is where to align the top edge of the wall mounting bracket.
NOTE: The wall mounting bracket does not need to be centered on the crossbar, but must be
located between the pillars.
33" / 838 mm
from floor
IMPORTANT: The wall bracket is intended to keep the scale from pulling off of the wall.
Ensure that the entire weight of the scale is on the floor and not on the wall bracket.
5. For stud walls, use a stud finder and locate any studs in the mounting area:
• For two (2) studs located within the mounting area (usually 16" / 406 mm on center) align
the outer mounting holes with the studs, level the wall bracket and mark all four screw
locations.
• For one (1) stud located within the mounting area align the inner mounting holes with the
stud, level the wall bracket and mark all four screw locations.
• For no studs located within the mounting area, level the wall bracket and mark all four
screw locations.
For concrete walls, level the wall bracket and mark all four screw locations
6. For stud wall mounting locations without a stud, use a screwdriver to drive the provided self-
drilling wall anchors into the wall. It is not recommended to use a power drill to set the wall
anchors.
For concrete wall mounting, install appropriate wall anchors at all marked screw locations (not
included). NOTE: The supplied wall anchors are not designed for use with a concrete wall.
7. Mount the bracket to the wall by either using the provided #8 x 1" Phillips flat head screws
into the self-drilling wall anchors or using the customer supplied appropriate flat head screws
long enough to anchor into the wall or the concrete anchors.
NOTE: The screws need to be a flat head type screw so there is adequate clearance for the
scale frame to slide into the wall bracket.
8. After the bracket is securely fastened to the wall, have two people lift the scale and place it
into the wall mounting bracket.
WARNING: The counterbalance actuators assist the end user when raising
or lowering the platform. The user needs to control the raising and lowering of the
platform. Keep feet, toes and fingers clear when raising or lowering the platform.