Télécharger Imprimer la page

Trumpf TruConvert AC 3025 Manuel Opérateur page 149

Masquer les pouces Voir aussi pour TruConvert AC 3025:

Publicité

Number
Message
50089
Undervoltage exter-
nal 24-V auxiliary
supply
50095
AC-DC module
hardware protection
alarm
50096
DC link precharge
unit alarm
50097
DC link discharge
unit alarm
50098
DC link could not
be charged.
50100
DC link relay could
not be closed.
50101
DC link relay was
forced to disconnect.
50102
Fan alarm
50115
Overvoltage filter
capacitor L1 RMS
50116
Overvoltage filter
capacitor L2 RMS
50117
Overvoltage filter
capacitor L3 RMS
50118
Anti-island detection
alarm L1
50119
Anti-island detection
alarm L2
50120
Anti-island detection
alarm L3
50121
Missmatch of inter-
nal and external N
50130
DC link relay dis-
connect not allowed
- DC link voltage
unstable.
50131
Grid code ride
through time excee-
ded.
50132
Grid does not
match grid code
requirements.
A67-0141-00.BKfr-0
01-11
Effect
Device switches off.
Device switches off.
No operation pos-
sible.
No operation pos-
sible.
No operation pos-
sible.
No operation pos-
sible.
Device switches off.
No operation pos-
sible.
Device switches off.
Device switches off.
Device switches off.
Device switches off.
Device switches off.
Device switches off.
No operation pos-
sible.
Failed to disconnect
from DC-Link.
Device switches off.
No operation pos-
sible.
2024-08-01
Cause
Action
Undervoltage exter-
Check the external
nal 24-V auxiliary
24-V auxiliary sup-
supply.
ply.
AC-DC module
Check for other
hardware protection
error messages.
alarm.
Precharge unit fai-
Contact service.
led.
Discharge unit fai-
Contact service.
led or balancer fai-
led.
Charging of DC link
Check DC link bus
bus failed.
and cabling of con-
nected components.
DC link relay could
Check external DC
not be closed.
link voltage.
DC link relay was
Check external DC
forced to disconnect.
link.
Fan is defictive or
Check the fan.
stuck.
Overvoltage filter
Check grid settings,
capacitor L1 RMS.
grid voltage L1 and
external devices.
Overvoltage filter
Check grid settings,
capacitor L2 RMS.
grid voltage L2 and
external devices.
Overvoltage filter
Check grid settings,
capacitor L3 RMS.
grid voltage L3 and
external devices.
Anti-island detection
Check grid settings
alarm L1.
and the installation.
Anti-island detection
Check grid settings
alarm L2.
and the installation.
Anti-island detection
Check grid settings
alarm L3.
and the installation.
Missmatch of inter-
Check cabling of N
nal and external N.
and PE.
DC link relay dis-
Check DC link.
connect not allowed
- DC link voltage
unstable.
Grid code ride
Review grid code
through time excee-
settings. Ride
ded.
throughs can be
part of active grid
code).
Grid does not
Review grid code
match grid code
settings. Require-
requirements (vol-
ments for voltage
tage and frequency).
and frequency can
be part of active
grid code).
Recherche des erreurs
Caused
by
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
AC-DC
module
143

Publicité

loading