4
Fasten the filler strip in place.
5
Push in the fastening bolt and turn it 90°.
Note: The mounting pieces on the left and right
of the appliance must be able to move.
Final assembly
1
Mount the appliance.
2
Tighten the left and right fastening bolts.
3
Fit the protective caps on the left and right.
4
Establish the electrical connection.
Note: The extractor hood housing can be concealed
within the top cabinet. In doing so, you must observe
the following:
‒
The false floor must not be placed on the
extractor hood housing.
‒
The front panel must not be secured to the
housing.
‒
Access must be available in order to change the
filter and for customer service.
24
¨
©
ª
Appliance width, 36" (90 cm):
You must also screw the appliance onto the side top
cabinets.
Connecting the pipes
Note: If an aluminum pipe is used, smooth the
connection area beforehand.
Exhaust air pipe, 6" (150 mm) diameter
(recommended size)
Attach exhaust air pipe directly to the air-pipe
connector and seal.
Exhaust air pipe dia. 4¾" (120 mm)
1
Attach reducing connector directly to the air-
pipe connector.
2
Attach exhaust air pipe to the reducing
connector.
3
Seal both joints appropriately.
Removing the appliance
1
Disconnect the electrical connection.
2
Disconnect the pipes.
3
Remove the metal grease filter.
4
Remove the protective caps from the fastening
elements.
5
Remove the appliance see section entitled
"Removing the appliance".