Flat ducts
The inner cross-section must correspond to the
diameter of the round pipes.
dia. 6" (150 mm) approx. 27
_
dia. 4
" (120 mm) approx. 26
▯
Flat ducts should have no sharp deflections.
▯
Use sealing strip for deviating pipe diameters.
20
^
)
sq in (177 cm
2
_
sq in (113 cm
2
)
Preparing the units
▯
The fitted unit must be level and have sufficient
load-bearing capacity.
▯
The max. weight of the extractor hood is 40 lbs
(18 kg).
Appliance dimensions and safety clearances
▯
Observe the appliance's dimensions.
▯
Comply with the safety clearances.
If the installation instructions for the gas cooking
appliances specify a different distance, the largest
distance must always be provided for.
Fitted units must be heat-resistant up to 194° F
(90 °C). The stability of the fitted unit must also be
guaranteed after the cut-out work.
To install the extractor hood in a top cupboard, the
extractor hood must be provided with the following
dimensions:
Width
24" (600 mm)
Depth
min. 12
/
5
Depth
min. 13 ¾" (350 mm) with lowering frame
Elevation
min. 16
9
/
Elevation
min. 24" (600 mm) with CleanAir air
recirculation module
1
Make cut-out for the exhaust air pipe. To do this,
make an opening in the top or back panel of the
fitted unit with an additional recess for the
power cord.
" (320 mm)
8
" (420 mm)
16