Télécharger Imprimer la page

Gaggenau AF210761 Notice D'utilisation Et De Montage page 20

Publicité

Flat ducts
The inner cross-section must correspond to the
diameter of the round pipes.
dia. 6" (150 mm) approx. 27
_
dia. 4
" (120 mm) approx. 26
Flat ducts should have no sharp deflections.
Use sealing strip for deviating pipe diameters.
20
^
)
sq in (177 cm
2
_
sq in (113 cm
2
)
Preparing the units
The fitted unit must be level and have sufficient
load-bearing capacity.
The max. weight of the extractor hood is 40 lbs
(18 kg).
Appliance dimensions and safety clearances
Observe the appliance's dimensions.
Comply with the safety clearances.
If the installation instructions for the gas cooking
appliances specify a different distance, the largest
distance must always be provided for.
Fitted units must be heat-resistant up to 194° F
(90 °C). The stability of the fitted unit must also be
guaranteed after the cut-out work.
To install the extractor hood in a top cupboard, the
extractor hood must be provided with the following
dimensions:
Width
24" (600 mm)
Depth
min. 12 
/
5
Depth
min. 13 ¾" (350 mm) with lowering frame
Elevation
min. 16 
9
/
Elevation
min. 24" (600 mm) with CleanAir air
recirculation module
1
Make cut-out for the exhaust air pipe. To do this,
make an opening in the top or back panel of the
fitted unit with an additional recess for the
power cord.
" (320 mm)
8
" (420 mm)
16

Publicité

loading

Ce manuel est également adapté pour:

Af 2 serieAf210791