Electrical connection
9
WARNING
Risk of electric shock
Parts inside the appliance can have sharp
edges. The connection cable can be damaged.
Do not bend or pinch connection cables
during installation.
The necessary connection information is located on
the identification plate in the appliance interior,
remove metal grease filter to access it.
Length of the connecting cable: Approx. 4
(1.30 m)
This appliance meets EC radio interference
suppression requirements.
9
WARNING
Risk of electric shock
It must always be possible to disconnect the
appliance from the power supply. The
appliance must only be connected to a
protective contact socket that has been
correctly installed.
The plug of the electric power cable must be
easily accessible after installation of the
appliance. If this is not possible, an all-pole
isolating switch must be integrated into the
permanent electrical installation according to
the conditions of overvoltage category III and
according to the installation regulations.
The permanent electrical installation must only
be wired by a professional electrician. We
recommend installing a residual-current circuit
breaker (RCCB) in the appliance's power
supply circuit.
The branch-circuit breakers ampacity, the wire sizes
and the connections must conform to the
requirements of the National Electrical Code or
Canadian Electrical Code and all local codes and
ordinances.
22
This appliance is connected with a plug
▯
Plug has to be conform with NEMA
CONFIGURATIONS FOR PLUGS AND
RECEPTACLES.
▯
The appliance must be properly grounded.
▯
Plug must be rated not less than type 6-20 P (2-
pole 3-wire grounding).
▯
Only a qualified electrician should connect the
plug.
▯
Install a socket outlet earthed in accordance
with regulations approx. 27" (700 mm) above the
floor behind the appliance. The socket outlet
must still be accessible after installation.
]
ft