3. INSTALLATION
The pumps are designed to be installed in a spray booth.
DESCRIPTION OF THE LABEL MARKING
Sames
STAINS FRANCE
II 2 G
Ex h IIB T1-T6
Gb
X
UKCA
CE
TYPE
P prod : xx bar / xx psi
P air : 6 bar / 87 psi
SERIE / SERIAL
TEMPERATURE CLASS - PUMP, MODEL 40C50
Temperature class
SAMES KREMLIN
Description
Manufacturer's brand
Manufacturer's address
: Use in explosive area
II: Group II
2: Category 2
Surface equipment intended for use in environment where explosive
atmospheres due to gases, vapors, mists are likely to occur
occasionally during normal operation.
G: Gas
Ex: Marking of conformity to European standards
h: Protection mode for non-electrical devices
IIB: Reference gas for equipment qualification
T1-T6: Temperature class range
Gb : Equipment protection level (gas Zone 1)
X : Special conditions apply to the use of the safe operation. Refer to
the instructions in the instruction manuals that accompany this
product.
UK CA : UK Conformity Assessment
Marking required for certain products placed on the market in Great
Britain (England, Wales, Scotland) on January 2021
CE : European conformity
Pump model
Maximum fluid pressure at the pump outlet
Maximum air supply pressure of the pump motor
Number given by Sames. The two first numbers indicate the
manufacturing year.
Maximum surface temperature
T2
- 3 -
300° C / 572°F
N° : 578.040.120-UK-2403