UPPER PACKING
Separate the piston rod from the motor and the
piston from the fluid section.
Unscrew wetting-cup (4) by means of the wrench
supplied with the pump.
Pull piston (3) upwards to remove seals (21 and
22) from upper packing (18).
Reinstall parts in reverse order. Be certain seals
(21 and 22) are installed properly (direction, order
and assembly dimension).
Tighten wetting-cup (4).
After reassembly, fill up the pump with solvent
and increase pressure to maximum in the fluid
section. Then stop the pump and open exhaust
valve to depressurize.
Retighten wetting-cup (4) by means of the
wrench, in order to be in accordance with the
opposite drawing.
REVERSING BLOCK (REFER TO DOC. 573.087.040)
Guards (air motor cover, coupling shields, housings ...) have been designed for
The manufacturer will not be held responsible for bodily injury or failure and / or
damage to property due to removal or partial removal of the guards
Disassemble cover (32) by removing the 3 CHc screws (33).
Dissociate female yoke (12) from reversing block lever (9).
Dismount reversing block by removing screws (10 and 8).
Reinstall the new reversing block in the reverse order of the disassembly sequence.
 CAUTION :
Before reassembling :
Clean the parts with the appropriate cleaning solvent.
-
-
Install new seals if it is necessary after having lubricated them with PTFE grease.
-
Install new parts if it is necessary.
SAMES KREMLIN
safe use of the equipment.
31.85 mm ±0.5
The number of spirals must equally be distributed on each fastening
parts in order to get the above dimension.