l Power supply must include a fault current breaker.
Dirt accumulation, high humidity or material damage on
the motor housing may lead to dangerous current surges.
l The commutator motors Type F 458 EL and F 460 Ex EL
are equipped with a thermal switch. All other commutator
motors are equipped with an integral overload cut-out
switch.
The motor is switched off automatically in case of over-
loading. After having cooled down, the motor can be
switched on again by actuating the Start/Stop switch.
l Motors with integral no-volt release are protected
against unintentional re-starting after a voltage
discontinuity ( name plate marked: U < ).
Only by actuating the Start/Stop switch the motor can
be switched on again.
l Make sure that motors without no-volt release
are secured against unintentional re-starting.
The pump is to be arranged in a way that no
friction and impinge sparks form.
Replacement of power supply cable
l When replacing the cables, the following
types have to be used at least :
F 414 / F 414 Ex
F 417 / F 417 EL
F 457 / F 457 EL
F 458 / F 458 EL / F 458-1
F 460 Ex / F 460 Ex EL / F 460-1 Ex
Motor
Supply Voltage
100 V -240 V
H 07 RN-F 5G 1,5
H 05 RN-F 2X 0,75
H 05 RN-F 2X 1,0
H 07 RN-F 3G 1,5 H 07 RN-F 2X 4
12 - 24 V
-
-
-
13