English

General

Hatco Toast-Qwik
Conveyor Toasters are shipped with most
®
components pre-assembled. Care should be taken when
unpacking the shipping carton to avoid damage to the unit and
the components enclosed.
WARNING
ELECTRIC SHOCK HAZARD: Unit is not weatherproof.
Locate unit indoors where ambient air temperature is a
minimum of 70°F (21°C) and a maximum of 85°F (29°C).
EXPLOSION HAZARD: Do not store or use gasoline or
other flammable vapors or liquids in the vicinity of this or
any other appliance.
FIRE HAZARD:
• Allow a minimum clearance of 1" (25 mm) along the
sides and rear of unit. Allow a minimum clearance of
12" (305 mm) in the front, measured from chamber
opening on toaster body. If safe distances are not
maintained, discoloration or combustion could occur.
• Do not locate toaster under shelving or closer than 12"
(305 mm) from the ceiling.
• Do not place anything on top of toaster. Do not
place toaster near or underneath curtains or other
combustible materials. Items near or on top of toaster
could catch fire causing injury and/or damage to the
toaster.
• In case of fire, disconnect toaster from power source
immediately. This allows unit to cool, making it easier
and safer to put out fire.
Locate unit at the proper counter height in an area that is
convenient for use. Location should be level and strong
enough to support weight of unit and contents.
NOTICE
Plug unit into a dedicated circuit. Do not use multiple
appliances on same circuit.
Do not locate unit in an area subject to temperatures above
85°F (29°C) or grease from grills, fryers, etc. Excessive
temperatures and grease could cause damage to unit.
Do not locate toaster in an area that restricts air flow
around front or rear of unit. Do not locate toaster in direct
discharge path of air conditioning vent or makeup air vent.
Form No. TQ3M-0519
CAUTION
1. Remove the unit from the carton.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
IMPORTANT OWNER INFORMATION section for
details.
2. Remove tape and protective packaging from all surfaces
of the unit.
3. Place the unit in the desired location.
• Locate the unit in an area where the ambient air
temperature is constant and between 70°F (21°C) and
85°F (29°C). Avoid areas that may be subject to active
air movements or currents (i.e., near exhaust fans/
hoods, air conditioning ducts, and exterior doors).
• Make sure the unit is at the proper counter height in an
area convenient for use.
• Make sure the countertop is level, made of non-
combustible material, and strong enough to support the
weight of the unit and its contents.
• Make sure all the feet on the bottom of the unit are
positioned securely on the countertop.
Always operate toaster with crumb tray installed.
4. For TQ3-400 models: Install the removable toast tray
underneath the discharge area.
Installing the Toast Tray (Model TQ3-400 only)