General

The Hatco Toast-Qwik
Conveyor Toaster is shipped with
®
all components pre-assembled. Care should be taken when
unpacking the shipping carton to avoid damage to the unit and
the components enclosed.
WARNING
ELECTRIC SHOCK HAZARD: Unit is not weatherproof.
Locate unit indoors where ambient air temperature is a
minimum of 21°C (70°F).
EXPLOSION HAZARD: Do not store or use gasoline or
other flammable vapors or liquids in the vicinity of this or
any other appliance.
FIRE HAZARD:
• Allow a minimum clearance of 25 mm (1") along the
sides and rear of unit. Allow a minimum clearance of
305 mm (12") in the front. If safe distances are not
maintained, discoloration or combustion could occur.
• Do not locate toaster under shelving or closer than
305 mm (12") from the ceiling.
• Do not place anything on top of toaster. Do not
place toaster near or underneath curtains or other
combustible materials. Items near or on top of the
toaster could catch fire causing injury and/or damage
to the toaster.
1. Remove the unit from the carton.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
IMPORTANT OWNER INFORMATION section for
details.
2. Remove tape and protective packaging from all surfaces
of the unit.
Crumb
Tray
Discharge Chute
Front View (TQ-400 Model shown)
Locate unit at the proper counter height in an area that is
convenient for use. The location should be level to prevent
the unit or its contents from falling accidentally and strong
enough to support the weight of the unit and contents.
Do not locate unit in an area subject to excessive
temperatures or grease from grills, fryers, etc. Excessive
temperatures could cause damage to the unit.
Toast Collector
Pan
BURN HAZARD: Do not remove crumb tray for cleaning
until toaster is cool.
Always operate toaster with crumb tray installed.
10
3. Place the unit in the desired location.
• Locate the unit in an area where the ambient air
temperature is constant and a minimum of 21°C (70°F)
and maximum of 29°C (85°F). Avoid areas that may be
subject to active air movements or currents (i.e., near
exhaust fans/hoods, air conditioning ducts, and exterior
doors).
• Make sure the unit is at the proper counter height in an
area convenient for use.
• Make sure the countertop is level and strong enough to
support the weight of the unit and food product.
• Make sure all the feet on the bottom of the unit are
positioned securely on the countertop.
4. If toaster is not level adjust the foot of each leg until level.
(TQ-10 models use 14 mm (9/16") open-end wrench to
adjust leg height.)
5. Install the front or rear discharge chutes. Refer to the "Front
or Rear Discharge Installation" procedure in this section.
CAUTION
NOTICE
6. Install the crumb tray.
a. Position the crumb tray directly below the stop pins
under the conveyor belt at the front of the toaster.
b. Slide the crumb tray into the toaster until the front of the
crumb tray meets the stop pins.
Stop Pins
Crumb
Tray
Installing the Crumb Tray