Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. Set flow adjustment before making wiring connections (Diagram 2). Flow
adjustment and manual ON-OFF operation are set by two different controls.
A. Turn valve on by holding gray ring stationary. Turn solenoid (black
knob) counterclockwise 1/4 turn.
B. Now turn the gray ring counterclockwise (the solenoid should turn with
it) until the water flows at the desired rate.
C. Turn valve off by holding the gray ring stationary. Turn solenoid (black
knob) clockwise finger tight 1/4 turn. The black knob must remain in
this "OFF" position for automatic operation.
D. Flow adjustment is now set.
5. WIRE CONNECTIONS (Diagram 3) Use 18 gauge wire to connect the
wires to the timer. Wiring that is to be buried alongside the pipes should be
APPROVED for UNDERGROUND use and for all splices use water tight
connectors.
Each valve has two wires. Either one may serve as the HOT wire which
is connected directly to a station output terminal in the timer. The other wire
is "COMMON" and may be joined to the common wires of other valves with
one wire running to the common terminal of the timer. Check operation
using the timer control.

REPAIR KITS

Two types of repair kits are available (Diagram 4)
1. SRK-1 Solenoid Replacement Kit. The SRK-1 kit will replace a defective
solenoid on models APAS-075 and APAS-100.
2. PRK-100 Piston Replacement Kit. The PRK-100 kit will replace a defec-
tive piston on models APAS-075 and APAS-100.
For technical assistance call us at 1-800-724-6247
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Apas-100

Table des Matières