General informations
AMFLO
®
MAG Smart has been designed as a volumetric flow sensor for measurement of conductive fluids.
The device is a precision measuring instrument and therefore must be handled with care during installation. Incorrect
handling can lead to loss of warranty. Use brass connections for connecting the device to the pipework.
Flow direction
Connecting cable
Technical data
Nominal sizes
Electrodes
Fluid
Nominal pressure
Liner
Flange
Outer casing
Gaskets
Protection class
Fluid temperature range
Ambient temperature
Min. electrical conductivity
Accuracy
Digital output
Range of measurement
Cable length
Wiring
Power supply
* Please check the chemical resistance of the device (liner, electrodes and gaskets) for the used medium!
Range of measurement (approved according to EN 1434 class 2, measurement dynamic 1:250)
Nominal diameter DN
mm
inch
qi (minimal flow)
m
3
qp (nominal flow)
m
3
qs (maximal flow)
m
3
v (qi)
m/s
v (qp)
m/s
Δp (qp/2)*
mbar
Flow at Δp = 100 mbar
m
3
Kvs
m
3
* equivalent to standard values of qp according to EN 1434
AMFLO
®
MAG Smart
Potential
equalisation
connection
DN 15 - 100
Stainless steel 1.4571
Water and other fluids*
PN 16, JIS 10K, ANSI 150
PPE Noryl
Chromed brass
Coated steel
NBR/EPDM
IP 67
T
= 0 - 60 °C
Fluid
T
= 2 - 55 °C
Amb
40 μS/cm
±0.5 % (±0.004 m/s slower than 0.5 m/s)
max. 200 Hz (pulse duration 2.5 ms at 200 Hz), SSR (Solid State Relais) passive, max. 48 V / 50 mA
0.015 - 5 m/s
5 m, fixed on sensor side
pulse and alarm outputs
24 VDC, 150 mA (galvanically isolated)
15
20
1/2
3/4
/h
0.012
0.02
/h
3
5
/h
3.3
5.7
0.019
0.018
4.72
4.42
66
38
/h
1.85
4.06
/h
5.84
12.82
Flow direction
25
32
40
50
1
1 1/4
1 1/2
2
0.028
0.048
0.08
0.12
7
12
20
30
8.5
14
22
35
0.016
0.017
0.018
0.017
3.96
4.14
4.42
4.24
37
19
30
24
5.75
13.76
18.26
30.62
18.20
43.5
57.7
96.8
Potential
equalisation
connection
Connecting cable
65
80
100
2 1/2
3
4
0.2
0.32
0.48
50
80
120
59
90
140
0.017
0.018
0.017
4.19
4.42
4.24
42
51
44
38.58
56.01
90.45
122
177
286
9