8. CLEANING AND MAINTENANCE
8.1 Routine maintenance
The routine and preventive maintenance basically consists in the weekly cleaning of the stainless steel parts with lukewarm soapy
water, rinsing abundantly and drying thoroughly. The unit must only be cleaned after first disconnecting the power supply upstream
from the equipment.
Should lime scale form on the bottom of the basin, clean with a vinegar solution or special products before rinsing abundantly with
water and drying.
Warning:
•
Under no circumstances should you use abrasive or corrosive detergents and utensils such as steel wool, brushes or metal
scrapers.
•
Bleach, hydrochloric acid and other compounds containing chlorine will damage the stainless steel.
•
The coloured parts must be cleaned with silicone wax.
•
The floor under the unit must not be washed with corrosive substances that might generate vapours damaging the equipment.
•
During cleaning, do not wash the equipment with jets of water .
8.2 Non-routine maintenance
The non-routine maintenance must be performed by qualified personnel in the event of a fault or anomaly, wherever possible with
the equipment disconnected from the power mains.
In this case, repairs or replacements might be required. The faulty parts must only be replaced with materials and components identical
to the originals or specified by the Manufacturer.
The replacement of components or the modification of the equipment by the user without written permission from the Manufacturer, or
the use of non-authorized spare parts, shall instantly cause the warranty to be void.
8.3 Possible errors
If the BASIN does not heat, check the power supply and make sure the working thermostat is not at the minimum setting.
If the HEATED COMPARTMENT does not heat, check the power supply and make sure the working thermostat is not at the minimum
setting, or that the heated cabinet's vents are obstructed.
If, after performing the checks indicated, correct operation is still not achieved, switch off the equipment and contact the supplier
without delay.
9
SCRAPPING
At the end of its service life, the equipment must be disconnected from the power mains before disassembling the various components.
Special care must be taken to avoid the risk of accidents associated with the form and weight of each component.
The various parts (electrical components, rubber piping, fairlead linings etc.) must be sorted so as to make the best possible
contribution to the protection of the environment in compliance with the laws in force.
TECHNICAL DATA
Compartment type
Overall dimensions mm:
•
L = length
•
P = depth
•
H = height
Depth with tray slide mm
Compartment dimensions
mm:
•
length
•
depth
•
height
Compartment capacity –
litres
Door type
N° of doors
Number of basins
Basin dimensions mm:
•
length
•
depth
•
height
Basin capacity GN
Water inlet diameter
Water outlet diameter
Basin power kW
Compartment power kW
Total power kW
Supply voltage
Max. weight (Kg).
A010302
Rev. 1
PDF created with FinePrint pdfFactory Pro trial version
Tabelle A:
TECHNICAL FEATURES OF BAIN-MARIE UNITS
EGB8
EGB
EGB 15
EGB 23
12
OPEN
OPEN
OPEN
OPEN
750
1125
1500
2250
800
800
800
800
900
900
900
900
1100
1100
1100
1100
550
825
1300
1920
650
650
650
650
440
440
440
440
155
235
370
545
/
/
/
/
/
/
/
/
1
1
1
1
630
960
1280
1930
510
510
510
510
210
210
210
210
2 1/1
3 1/1
4 1/1
6 1/1
3/4"
3/4"
3/4"
3/4"
1/2"
1/2"
1/2"
1/2"
2
3
3
6
/
/
/
/
2
3
3
6
230V
380V
380V
380V
1N
3F+N
3F+N
3F+N
70
85
100
135
EAB 8
EAB 12
EAB 15
EAB 23
CABINE
CABINE
CABINE
CABINE
T
T
T
750
1125
1500
800
800
800
900
900
900
1100
1100
1100
550
825
1300
650
650
650
440
440
440
155
235
370
Battente
Battente
Battente
Battente
1
2
3
1
1
1
630
960
1280
510
510
510
210
210
210
2 1/1
3 1/1
4 1/1
3/4"
3/4"
3/4"
1/2"
1/2"
1/2"
2
3
3
/
/
/
2
3
3
230V 1N
380V
380V
380V
3F+N
3F+N
3F+N
85
108
115
Pagina 9 di 22
http://www.fineprint.com
ECB 8
ECB 12
ECB 15
HEAT
HEATE
HEATE
T
ED
D
D
2250
750
1125
1500
800
800
800
800
900
900
900
900
1100
1100
1100
1100
1920
550
825
1300
650
650
650
650
440
440
440
440
545
155
235
370
Batten
Battente
Battente
te
4
1
2
3
1
1
1
1
1930
630
960
1280
510
510
510
510
210
210
210
210
6 1/1
2 1/1
3 1/1
4 1/1
3/4"
3/4"
3/4"
3/4"
1/2"
1/2"
1/2"
1/2"
6
2
3
3
/
1.1
1,6
1,6
6
3.1
4.6
4.6
230V
380V
380V
1N
3F+N
3F+N
146
90
110
120
GB
ECB 23
HEATE
D
2250
800
900
1100
1920
650
440
545
Battente
4
1
1930
510
210
6 1/1
3/4"
1/2"
6
2,2
8.2
380V
3F+N
150