Battery charge level
♦
The status will be shown on the battery display
LED
as follows:
RED/ORANGE/GREEN = maximum charge
RED/ORANGE = medium charge
RED = low charge – charge the battery
Overload warning
♦
If the appliance is in danger of overloading,
the overload warning
appliance switches off.
Setting the cutting angle
You can select the cutting angle using the cutting
angle scale
.
■
Undo the wing screw
preselector. Set the desired angle on the cutting
angle scale
using the top edge of the raised
black metal part (see fig. C). Retighten the wing
screw
.
The left recess in the base plate is for a cutting
angle of 45°. (Fig. B)
Fig. C: Setting the cutting angle to 45 degrees
Setting the cutting depth
NOTE
►
Select a cutting depth of approx. 3 mm more
than the thickness of the material. This ensures
that you achieve a clean cut.
♦
Undo the locking screw
cutting depth on the cutting depth scale
using the reference marks (see arrow in fig. D).
Retighten the locking screw
│
GB │ IE
■
26
lights up briefly. The
of the cutting angle
0
and set the desired
.
Fig. D: Setting the cutting depth
Working with the circular saw
1. Switch on the appliance – as described in
"Switching on and off" – and then place it
with the front edge of the base plate
material.
2. Align the machine using the rip fence
using a marked line.
Maintenance and cleaning
WARNING! RISK OF INJURY! Always
switch the appliance off and remove
the battery before carrying out any
work on the appliance.
The cordless hand-held circular saw is mainte-
nance-free.
■
The appliance must always be kept clean, dry
and free from oil or grease.
■
Never allow liquids to get into the appliance.
■
Use a soft, dry cloth to clean the housing.
Never use petrol, solvents or cleansers which
can damage plastic.
■
The blade guard must always move freely and
close automatically. Therefore, keep the area
around the blade guard clean at all times. Re-
move dust and chips by blowing them out with
compressed air or with a brush.
■
If a lithium-ion battery is to be stored for an
extended period, the charge level should be
checked regularly. The optimum charge level is
between 50% and 80%. The optimum storage
environment is cool and dry.
on the
or by
PHKSA 12 A2