9.
Faults and troubleshooting
Fault
Operating vacuum not
en
achieved or is too low, and
the compressed air unit is
running
cs
da
Vacuum plate changed over
es
to vacuum connection: Oper-
ating vacuum not achieved or
is too low, and the vacuum
fi
pump is running
fr
The clamping face of the va-
cuum plate is damaged
The restraining force is insuf-
hr
ficient to machine the work-
piece
hu
it
10. Cleaning
Clean with a cloth or compressed air.
lt
Do not use any corrosive cleaning agent.
11. Storage
nl
Store in an enclosed dry room.
Do not store in the vicinity of acidic, aggressive, chemical substances, solvents, humidity and dirt.
Protect against direct sunlight.
pl
Store at temperatures between +15° C and +35 °C.
Relative atmospheric humidity max. 60%
12. Spare parts
pt
Use only original replacement parts and wearing parts.
Rubber adapter mat
Adhesive film
ro
13. Disposal
Comply with the national and regional environmental protection and disposal regulations for correct disposal or recycling.
ru
Segregate items into metals, non-metals, composite materials and consumables and dispose of them responsibly.
14. Technical data
Article no. / type
sl
Length
Width
sv
Height
14
Possible cause
Leaky compressed air hoses
Dirt between the workpiece
and vacuum plate
Seal defective or not fitted
Kink in the compressed air
hoses
Shut-off valve not fully turned
on.
Leaky vacuum hoses
Dirt between the workpiece
and vacuum plate
Seal defective or not fitted
Kink in the vacuum hoses
Defective machining of the
workpiece
Clamping area is too small
Diameter of the vacuum
hoses too small, or vacuum
hoses too long
Power of the vacuum pump
insufficient
Action
Exchange the compressed air
hoses
Clean the faces of the work-
piece and vacuum plate
Change the seal
Align the compressed air
hoses correctly
Turn the shut-off valve fully
on
Change the vacuum hoses
Clean the faces of the work-
piece and vacuum plate
Change the seal
Align the vacuum hoses cor-
rectly
Check the machining pro-
gram
Increase the clamping area
Use additional restraints for
workpiece
Increase the diameter of the
vacuum hoses, or reduce the
length of the vacuum hoses
Increase the power of the va-
cuum pump
384905 / VSV0
200 mm
125 mm
21 mm
Performed by
Trained specialist for mechan-
ical work
Trained person
Trained specialist for mechan-
ical work
Trained person
Trained specialist for mechan-
ical work
Trained specialist for mechan-