User manual
Connectivity for KRYPTON 401 :
The machine is equipped with a female connector for a remote control.
The specific 7-point male connector (optional ref. 046238) can be used to connect the different types of remote control. For wiring, follow the
diagram below.
Type of remote control
Foot pedal
Type of remote control
C5
C5:
From a previously created C5 list of 5 JOBs, this simple automation mode using the Remote Control connector allows JOBs to be recalled via a PLC
(see note on the website -https://planet.gys.fr/pdf/spdoc/fr/CONNECT_5.pdf).
44
Translation of the original
instructions
Wire description
VCC
Common/Earth
Interrupteur
Switch
Wire description
10 V
Cursor
Common/Earth
Switch
AUTO-DETECT
ARC ON
REG I
KRYPTON 231 DC FV / 321 DC TRI / 401 DC TRI
Pin
4
1
3
2
5
4
1
6
7
5
External view
Pin
A
B
G
F
A
C
B
E
D
C
External view
D
E
F
G
2
To use C5 mode, a
specific optional
connector is required.
Installation :
see I-5 - page 3