Télécharger Imprimer la page

GYS KRYPTON 401 DC TRI Mode D'emploi page 33

Publicité

Les langues disponibles
  • FR

Les langues disponibles

User manual
4T
4T LOG
Gas purge
THUMBWHEEL NAVIGATION
Rotating the thumbwheel allows
- adjustment to the welding current
- to change a parameter of the welding cycle
Pressing the thumbwheel allows
- access to the welding cycle by selecting the first parameter
- access to the parameter settings and confirm the modification
TIG (GTAW) WELDING MODE
INSTALLATION AND GUIDANCE
• DC TIG welding requires a protective gas shield (Argon).
• Connect the earth clamp to the positive (+) plug connector. Connect the torch power cable to the
negative (-) socket, along with the torch button(s) and gas connector(s).
• Ensure that the torch is properly fitted and that the consumables (clamps, collet bodies, diffusers and nozzles) are not worn out.
• The electrode is determined by the welding current of the TIG process.
RECOMMENDED COMBINATIONS
(mm)
0.3 - 3
2.4 - 6
4 - 8
6.8 - 8.8
9 - 12
ELECTRODE SHARPENING
For optimum results, it is advised to use an electrode sharpened in the following way:
d
SELECT IGNITION MODE
Lift: contact ignition (for applications sensitive to HF disturbances)
HF: high frequency ignition without contact between the tungsten electrode and the workpiece.
Touch.HF: time-delayed high frequency ignition after contact between the tungsten electrode and the workpiece
1
2
1
2
Translation of the original
instructions
x
4T trigger mode.
x
4T LOG trigger mode.
+
x
Gas purge activation button for the torch.
Current (A)
Ø Electrode (mm)
3 - 75
60 - 150
100 - 200
170 - 250
225 - 320
L = 3 x d for a low current.
L = d for a high current
L
3
1- Position the torch nozzle and electrode tip on the workpiece and press the
torch button.
2- Tilt the torch until a distance of about 2-3 mm separates the tip of the electrode
and the workpiece. The arc starts.
3- Move the torch to the regular position to start the welding cycle.
3
1- Place the torch in the welding position above the workpiece (distance of about
2-3 mm between the electrode tip and the workpiece).
2- Press the torch button (the arc is initiated without contact using high voltage HF
ignition pulses).
3- The initial welding current circulates, and the process continues as per the wel-
ding cycle.
KRYPTON 231 DC FV / 321 DC TRI / 401 DC TRI
Ø Nozzle (mm)
1
6.5
1.6
8
2
9.5
2.4
11
3.2
12.5
Argon flow rate (L/min)
6 - 7
6 - 7
7 - 8
8 - 9
9 - 10
33

Publicité

loading

Ce manuel est également adapté pour:

Krypton 321 dc triKrypton 231 dc fv