User manual
ADJUSTING THE WELDING INTENSITY
The following settings indicate the usable current range depending on the type and diameter of the electrode. The ranges are quite broad, as they vary
depending on the application and the welding position.
Electrode Ø (mm)
1.6
2.0
2.5
3.15
4.0
5
6.3
CHOOSING COATED ELECTRODES
• Rutile electrodes: very easy to use in any position.
• Basic electrodes: it can be used in all positions and is suitable for safety work due to its increased mechanical properties.
• Cellulosic electrodes: very dynamic arc with a high melting speed, its suitability for use in all positions makes it ideal for pipeline work.
MMA - ADVANCED MENU
It is possible to access the advanced weld cycle settings. To access these advanced settings:
1- Press and hold the thumbwheel (> 3 seconds)
SEt
UP
2-
By scrolling with the thumbwheel, the following advanced settings can be selected:
Parameter
H.S.t
HotStart duration
A.St.
Anti-Sticking
LOCK / UNLOCK
The product lock prevents accidental adjustment.
Locking:
To lock the product, hold down the button
buttons are enabled, and the thumbwheel allows a variation around the current value previously set to +/- a percentage defined by the tolerance
tol
parameter
.
Unlocking:
To unlock the unit, press and hold the
Enter the code (000 by default) with the thumbwheel to unlock the machine.
Un
Loc
The code is accepted. All buttons are reactivated.
Cod.
Err
The code is incorrect.
After 3 incorrect attempts to enter the code, the display shows «Ser. Cod.» for 2 seconds. The display then shows a
Ser.
Cod.
flashing 6-digit code that must be entered with the thumbwheel to release the lock. This code is made up of six digits and
cannot be changed. It is: 314159.
The default code 000 can be changed via the SETUP menu. See following pages for details.
Translation of the original
instructions
Rutile E6013 (A)
30-60
50-70
60-100
80-150
100-200
150-290
200-385
Con
FIG.
Setting
Standard
0.0 - 2.0 sec.
X
ON-OFF
X
for more than 3 seconds. The display briefly shows
button, the display will show
KRYPTON 231 DC FV / 321 DC TRI / 401 DC TRI
Basic E7018 (A)
30-55
50-80
80-110
90-140
125-210
200-260
220-340
Pulse
HotStart is an overcurrent on ignition that prevents the elec-
X
trode from sticking to the workpiece.
The anti-stick function is useful for removing the electrode
X
safely in the event it sticks to the workpiece (the current
is switched off automatically).
Loc
Cod.
___
.
Cellulosic E6010 (A)
-
-
60-75
85-90
120-160
110-170
-
and the product is now locked. No
41