DESCRIPTION
Quadra is suitable for panel/ceiling or wall installations and surface mounting either in a
horizontal or vertical plane. A Flush Mount Kit (BE 1009000075 / NL/DE 8000000020) is available
as an accessory. Ø100mm ducting (flexible or rigid) can be attached providing rear exit as
standard or side exit with the Flush Mount Kit. Adaptors for rectangular ducting can be used. For
wall installations a Wall Kit (BE 1009000009 NL/DE 8000000002) can be used. Please see our
catalogue or web site (www.vent-axia.com) for more information on alternative ducting and
termination options. A Filter (BE 1009000076 NL/DE 8000000021) is available as an accessory.
A. INSTALLATION
A backdraught shutter is supplied. It is packed inside the product during transport and is designed
to block the duct when the fan is off in order to prevent cold draughts from outside entering the
building. If you are going to set the fan up to extract air continuously (constant trickle), you do not
necessarily need it. To use it, push it on to the end of the exhaust spigot with the hinges on the
flaps vertical (fig.1).
IMPORTANT: Be careful to avoid joists and hidden pipes or cables when cutting or drilling holes.
SURFACE MOUNTING (PANEL/CEILING)
1.
Remove the front cover by slackening the 2 cover screws by 2 turns (fig.2.) Lift the cover
away from the bottom edge then the top edge.
2.
Cut a ∅105mm hole and suitable screw holes in the panel, ensuring that there is sufficient
space for the product to be installed and that the optional Filter (fig.3) could be removed for
cleaning. The cardboard fitment in the packaging can be used as a template.
3.
Set-up the appropriate speed selection and other features as outlined in Section B.
4.
Remove the small internal cover that covers the terminal block in the top right corner (fig.3).
5.
Attach the ducting to the spigot and locate the fan into the hole in the panel. Feed wiring
through the hole in the chassis next to the terminal block as you do so. (fig. 4)
6.
Secure into position using appropriate screws and rawl plugs.
7.
Select and follow the appropriate wiring diagram in Section C.
8.
Replace the internal cover over the terminal block.
9.
Ensure the impeller rotates freely.
10. Replace the front cover assembly and tighten the two screws.
11. Switch the mains power supply on and check the fan is operating correctly.
SURFACE MOUNTING (WALL)
For through-the-wall installations, a Wall Kit (BE 1009000009 NL/DE 8000000002) can be
used.
1.
Remove the front cover by slackening the 2 cover screws by 2 turns (fig.2.) Lift the front
assembly away from the bottom edge, and then from the top edge.
2.
Cut a ∅117mm hole through the wall, ensuring that there is sufficient space for the product to
be installed and that the optional filter (fig.3) can be removed for maintenance. The cardboard
fitment inside the packaging can be used as a template.
3.
Insert the wall sleeve with the larger diameter sleeve on the room-side and cement the ends
into position flush with the wall faces. The wall sleeve should be angled downwards, away
from the fan, to allow any condensation to drain to outside.
4.
Outside grille (available separately): using the grille's back plate as a template, mark the fixing
hole centres on the wall. Drill and plug the wall and fix the grille into position. Ensure the
louvres are pointing downwards.
5.
Set-up the appropriate speed selection and other features as outlined in Section B.
6.
Remove the small internal cover that covers the terminal block in the top right corner (fig 3).
7.
Using the fan chassis as a template, carefully slide the spigot into the wall liner and mark the
fixing hole centres on the wall.
8.
Drill and plug the wall using the fixings provided.
9.
Feed the wiring through the hole near the terminal block (fig.4) and secure the fan into
position using the screws provided.
10. Select and follow the appropriate wiring diagram in Section C.