Environmental
Temperature
Operating
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
10° to 35°C (50° to 95°F) with a maximum temperature
gradation of 10°C per hour
NOTE:
For altitudes above 2950 feet, the maximum
operating temperature is derated 1°F/550 ft.
–40° to 65°C (–40° to 149°F) with a maximum temperature
gradation of 20°C per hour
20% to 80% (non-condensing) with a maximum humidity
gradation of 10% per hour
5% to 95% (non-condensing) with a maximum humidity
gradation of 10% per hour
0.26 Gms from 5–350 Hz for 5 minutes in operational
orientations
1.54 Gms from 10–250 Hz for 10 minutes in all orientations
Half sine shock in all operational orientations of 31 G plus or
minus 5% with a pulse duration of 2.6 ms plus or minus 10%
Half sine shock on all six sides of 71 G plus or minus 5% with
a pulse duration of 2 ms plus or minus 10%
Square wave shock on all six sides of 27 G with a velocity
change at 235 in/sec or greater
–16 to 3,048 m (–50 to 10,000 ft)
NOTE:
For altitudes above 2950 feet, the maximum
operating temperature is derated 1°F/550 ft.
–16 to 10,600 m (–50 to 35,000 ft)