WARNINGS: • All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C). • Nice S .p .A. reserves the right to apply modifi-
cations to products at any time when deemed necessary, maintaining the same intended use and functionality .
Product Type
Maximum torque on start-up
Nominal torque
Maximum operating
cycle frequency
at nominal torque *
Maximum continuous operating
time at nominal torque **
Opening time
Durability
Peak power supply
Peak power absorption on start-up
Maximum power at nominal torque
Insulation class
Emergency power supply
Courtesy light
Flashing light output
BLUEBUS output
STOP Input
S.S. input
OPEN Input
CLOSE Input
Radio AERIAL input
Radio connector
Programmable functions
Operating temperature
Protection rating
Dimensions
Weight
Note:
(*) At 50°C the maximum operating frequency is 40 cycles/hour
(**) At 50°C the maximum continuous operating time is 5 minutes.
TECHNICAL CHARACTERISTICS OF THE PRODUCT
S4BAR is an electromechanical road barrier for residential use. Controls opening and closing of
an access point with a maximum width of 4 m. Complete with electronic control unit
100 (80 with XBA4 accesory) cycles / hour
between 80,000 and 500,000 manoeuvre cycles according to the conditions stated in Table 2
For 1 flashing light LUCYB, MLB or MLBT (12 V - 21 W lamp)
1 output with maximum load of 12 Bluebus units
For normally closed, normally open or 8.2 kΩ; constant resistance contacts in self-learning mode
(a change from the memorised state prompts the "STOP" command)
For normally open contacts (closure of the contact prompts the Step by Step command)
For normally open contacts (closure of the contact prompts the OPEN command)
For normally open contacts (closure of the contact prompts the CLOSE command)
SM connector for receiver types SMXI, SMXIS or OXI, OXIT and OXIFM
8 ON-OFF type functions and 8 adjustable functions (see tables 6 and 7)
Self-learning of devices connected to the BlueBus output. Self-learning of "STOP"
Functions in self-learning mode type devices (contacts NO, NC or 8,2KΩ). resistance).
Learning of pole opening and closing positions and calculation of the points of deceleration and
1146 x 330 h 179,5; pole: minimum 2 m - maximum 4 m
100 Nm
25 Nm
10 (8 with XBA4 accesory) minutes
≥ 4 s (>5s with XBA4 accesory)
230 Vac (50/60Hz)
300W
200 W
I
Yes (with PS124 accessory)
With XBA7 LED flashing accessory
52 Ω for RG58 or similar type cable
partial opening
-20° C ... +50° C
IP 44
35 kg