- The following models included in the M range:
Model M-170 and its different versions.
o
Model M-180 and its different versions.
o
Model M-100 and its different versions.
o
- All models included in the IZ series and the Hidro series.
7.1.
Primary Air Channeling Kit for Insertable and M series models
The models included in the first two points of section "7. PRIMARY AIR CHANNELING" have a primary air
ducting system located at the rear of them by coupling a Ø 120 mm nozzle, which is not included in the equipment
and should be purchased separately.
We must bear in mind that this type of primary air intake ducting is not adjustable, so the air flow contribution
will be continuous and total.
WARNING: The installation must be carried out by qualified personnel, taking into account that if
this is not the case, the manufacturer declines all responsibility for the person who carried out the
installation.
7.2.
Primary Air Ducting Kit for IZ and Hidro models
This KIT allows us to channel the primary air inlet from a room other than the
one where our equipment is installed or from outside, if we wish, thus being able to
obtain a watertight equipment. The KIT is made up of 2 Ø 80 mm nozzles that we
must screw on the back of the equipment and to which we can install intake tubes of
said diameter if necessary.
Below, we show a series of images that will help us install the kit discussed at this point.
For the correct installation of the primary air channeling kit, it is necessary to remove the pre-cut holes that
present the holes into which each of the nozzles is attached. Once removed, the nozzles fit into the gap and are
screwed into the corner holes on the back of the equipment.
We must take into account that, regardless of whether the Kit has been installed or not, the regulation of the
primary air inlet is carried out in any case from the system that the equipment has installed on the front and located
more specifically under the door (See section " 5.3.1. Primary Air Regulation for IZ and Hydro models" of this manual).
WARNING: The installation must be carried out by qualified personnel, taking into account that if
this is not the case, the manufacturer declines all responsibility for the person who carried out the
installation.