Installation and Operating Instructions
EN
Air purifier AirPal Go 300/600 H
6�3 Parameter mode configuration
To access the parameters mode, in normal operating mode press MODE continuously (approx. 2s) until the user menu
appears on the screen (date setting, time programming, identifier, parameters, reset of the G4 filter operating time,
reset of the operating time filter H14 and control panel reset). With the UP and DOWN keys select PAr and press
MODE, accessing the parameter mode at that moment.
IIn parameter mode the functions of the buttons are as follows:
- ON/OFF: Exits parameter mode.
- MODE: Accepts the value of the displayed parameter and goes to the next parameter.
- GO UP: Increases the value of the parameter.
- GO DOWN: Decrease the value of the parameter.
Setting of parameters
P1. RUNNING HOURS G4 FILTER FOR DIRTY FILTER INDICATION (range: 0ff, 00001h to 09000h; default: 04000h
OFF Function disabled
00001...09000 Function enabled
P2. HOURS OF OPERATION FILTER H14 FOR DIRTY FILTER INDICATION (range: 0ff, 00001h to 09000h; default:
07305h)
OFF Function disabled
00001...09000
Function enabled
P3. MINIMUM VOLTAGE FAN SPEED (range: 0.0V to 5.0V; default: 2.0V)
P4. MAXIMUM VOLTAGE FAN SPEED (range: 6.0V to 10.0V; default: 9.5V)
6�4 Time schedule
To access the time programming mode, in normal operating mode press MODE continuously (approx. 2s) until the user
menu appears on the screen (date setting, hourly programming, identifier, parameters, reset of the G4 filter operating
time, reset of the H14 filter operation and regulator reset). With the UP and DOWN keys select PrOG and press MODE,
accessing at that time the time programming mode.
In time programming mode the functions of the buttons are as follows:
- ON/OFF:
Short press: Exits the time programming mode.
Long press (~1s): Copy the programming of the previous day to the current day. The icon is displayed as confirmation
of the copy of the day.
- MODE:
Select the period (day, periods 1 and 2, and reduced period), and the setpoints for those periods..
- GO UP / GO DOWN:
Modify the time value and the corresponding setpoint.
Displays in schedule mode:
Fig�7
Mode time
schedule
Setpoint speed
Lüftergeschwindigkeit
Ventilator
0% 100%
jetzt
Scheduled time
Unscheduled time
Scheduled period
Period 1
Ausgewählten Tag programmieren
Period 2
LUN
Montag
MAR
Dienstag
MIE
Mittwoch
Reduced period
JUE
Donnerstag
VIE
Freitag
SAB
Samstag
DOM
Sonntag
10
50 +
Setpoint speed period 1
30 +
Setpoint speed period 2
OFF+
Reduced period speed setpoint
12.30
--;--
Start period 1
End period 2
Start period 1
End period 2
The reduced period is that period outside
the scheduled hours for periods 1 and 2