Installation and Operating Instructions
Air purifier AirPal Go 300/600 H
Icon
Mon Tue Wed Thu Fri Sat Sun
Indication
Fan speed setpoint:
Selection range: 0% ... 100%. Display: 0% ... 99%, 100% = HIGH
= 0%: Fan off.
> 0%: Fan on.
O ... 99 ... H1
With control panel off in manual mode, these digits remain off.
In parameter mode it indicates the parameter number.
OFF On
23:45
On / off operating status (manual mode).
OFF On
Current time (programming mode).
OO:OO 23:59
In parameter mode it indicates the value of the parameters.
In schedule mode it indicates the time that is programmed as start or stop.
G4 filter operating hours (HG + operating time):
HG
O 1543
Filter operating hours H14 (HH + operating time):
HH
O 3822
Identifier (ID + code):
id
A23FO
Manual mode.
Operation according to the on / off and the selected manual setpoint.
Schedule mode.
Operation according to the schedule
Programming period 1 (start and end).
Programming period 1 (start and end).
Programming period 2 (start and end).
Reduced programming period.
In schedule, indicates the copy of the day.
Weekday.
In time programming it indicates the day of the week that is being program-
med.
Not used.