WARNING
FIRE HAZARD
• A clothes dryer must be exhausted
outdoors.
DO NOT exhaust dryer into a chimney,
a wall, a ceiling, an attic, a crawl space
or any concealed space of a building.
• A clothes dryer produces combustible
lint. If the dryer is not exhausted
outdoors, some fi ne lint will be expelled
into the laundry area. An accumulation
of lint in any area of the home can
create a health and fi re hazard.
• The dryer must be connected to an
exhaust outdoors.
• Regularly inspect the outdoor exhaust
opening and remove any accumulation
of lint around the outdoor exhaust
opening and in the surrounding area.
WARNING
FIRE HAZARD
DO NOT allow combustible materials
(for example: clothing, draperies/
curtains, paper) to come in contact
with exhaust system. The dryer MUST
NOT be exhausted into any gas vent
a chimney, a wall, a ceiling, or any
concealed space of a building which
can accumulate lint, resulting in a fi re
hazard.
DO NOT screen the exhaust ends of the
vent system, or use any screws, rivets
or other fasteners that extend into the
duct to assemble the exhaust system. No
screen, grate, or guard
of any mesh
size is allowed
to cover the
exhaust opening.
Lint can become
caught in the screen,
grate, guard, or on the screws or
rivets, clogging the duct work and
creating a fi re hazard as well as
increasing drying times. Use an
approved vent hood to terminate the
duct outdoors, and seal all joints with
metal foil tape. All male duct pipe fi ttings
MUST be installed downstream with the
fl ow of air.
PRE INSTALLATION REQUIREMENTS
WARNING
FIRE HAZARD
Never exceed more than 4-90˚ elbows in the
exhaust duct system. Exceeding the length
of duct pipe or number of elbows allowed
in the "MAXIMUM LENGTH" charts can
cause an accumulation of lint in the exhaust
system. Plugging the system could create a
fi re hazard, as well as increase drying times.
MAXIMUM LENGTH of 4" (102 mm)
Rigid Metal Duct
VENT HOOD TYPE
(Preferred)
4" (10.2 cm) louvered 2.5" (6.35 cm)
0
125 ft. (38 m)
1
115 ft. (35 m)
2
105 ft. (32 m)
3
95 ft. (29 m)
4
85 ft. (26 m)
WARNING
FIRE HAZARD
DO NOT install fl exible plastic or fl exible
foil venting material.
DO NOT exceed 8 ft. (2.4 m) duct length
if installing semi-rigid venting.
DO NOT use screws, rivets or other
fasteners that extend into the duct to
assemble the exhaust system.
Exhaust direction
Directional exhausting can be accomplished
by installing a quick-turn 90° dryer vent elbow
directly to exhaust outlet of dryer. Dryer vent
elbows are available through your local parts
distributor or hardware store.
See also CLEARANCE
REQUIREMENTS.
13
110 ft. (33.5 m)
100 ft. (30.5 m)
90 ft. (27.5 m)
80 ft. (24.5 m)
70 ft. (21.5 m)