This machine is only electrically safe if it is correctly connected to an efficient earth system in compliance with current
safety regulations.
Connect the boiler to a 230V single-phase earthed power supply using the supplied three-pin cable, observing correct
LIVE-NEUTRAL polarity.
Use a double-pole switch with a contact separation of at least 3 mm.
When replacing the power supply cable, fit a harmonised HAR H05 VV-F' 3x0.75 mm
of 8 mm.
Access to the power supply terminal block
• disconnect the boiler from the mains power supply using the two-pole switch;
• remove the two screws fixing the control panel to the boiler;
• rotate the control panel;
• remove the cover and access the wiring area (figure 11).
The 2A fast-blowing fuses are incorporated in the power supply terminal block (to check and/or replace the fuse, pull out
the black fuse carrier).
(L) = Live (brown)
(N) = Neutral (blue)
= Earth (yellow-green)
(1) (2) = Contact for ambient thermostat
IMPORTANT:
respect polarity L (LIVE) - N (NEUTRAL).
Figure 11
WARNING
: If the appliance is directly connected to an underfloor system, install a safety thermostat to prevent
the latter from overheating.
INSTRUCTIONS FOR FITTERS
17. ELECTRICAL CONNECTIONS
21
cable with a maximum diameter
2
7864176 - en