Télécharger Imprimer la page

Textron Jacobsen AR522 Manuel Du Revendeur page 23

Publicité

Les langues disponibles

Les langues disponibles

6.2
CONTROLLER LAMPS______________________________________________________
The controller is a solid state device that monitors and
controls electrical functions. The controller receives input
signals from various switches and sensors throughout
the machine and transmits output signals to operate
relays, solenoids and warning lights. It controls and
resets timers and contains built in logic to control certain
machine functions.
Each input and output signal is displayed through lamps
located on top of the controller. A closed input switch
indicates an active circuit and will turn an input lamp on.
An open switch an inactive circuit and will turn a lamp off.
Outputs are active when their lights are on.
Lamp On - Circuit is active
Lamp Off - Circuit is inactive
Lamp
1,2,3,4
Program Select (1, 3 and 4 are not used)
5
Brake Switch
6
Seat Switch
7
Traction Control Switch
8
Mow Switch
9
Joystick - Lower
10
Joystick - Raise
11
Hydraulic Oil Level Switch
12
Neutral Switch
13
Not Used
14
Keyswitch - Glowplug
15
Keyswitch - Start
16
Joystick Active
17
Hydraulic Filter Switch
18
Engine Oil Pressure Switch
Controller Functions by Lamp Number
INPUTS
Circuit
INPUTS
PROBLEM SOLVING
It is important to note that in some cases a lamp or group
of lamps must be on or off for a condition to be true. For
example, to start the mower the Mow Switch must be
OFF (lamp 8 off) while the Neutral Start Switch (lamp 12),
Brake Switch (lamp 6) and Fuel Valve Hold Coil (lamp 27)
must be ON.
NOTICE
For factory assistance with troubleshooting controller
problems, please note the controller hardware
revision and software version located on the lower
right corner of the controller. Controllers with equal or
greater revision levels will be backward compatible.
OUTPUTS
Lamp
19
Hydraulic Filter Light
20
Hydraulic Oil Level Light
21
Not Used
22
Glowplug Light
23
Lower Solenoid
24
Raise Solenoid
25
Glowplug Relay
26
Start Relay
27
Fuel Solenoid - Hold
28
Not Used
29
Audible Alarm
30
Mow Solenoid
31
Fuel Solenoid - Pull
32
Power-Ignition
33
Power-Lights
OUTPUTS
Circuit
6
23

Publicité

loading

Ce manuel est également adapté pour:

Jacobsen ar522-t4i68131