PUMP'S CONNECTIONS
ELECTRIC CONNECTION
Ensure the power supply earthing system is fully functional and corresponding to laws. A high sensitivity differential switch
(0.03A) is also recommended. Check that the nominal values of the pump are compatible with those of the electric plant.
Connect the electrical cable to the power supply and check the lightining of the display. Never install the pump in parallel
to inductive loads (eg motors), but, if this is strictly necessary, use a "relay".
Inside the pump there are two protections: a varistor and a fuse.
HYDRAULIC CONNECTION
ATTENTION!!!!!!!!!
Before any kind of operation on the pump it is necessary to read with attention the Safety toxicological data
sheets of the dosed chemical with the purpose to define the behaviors and the safety devices that must to be
followed.
FOOT FILTER
LEVEL PROBE MOUNTING (optional)
Rev 3.0
A - Power cable, 230 V- 50Hz (upon request : 115 ~ )
B - Level probe connector (3 and 4 contacts). OPTIONAL
C - Watermeter connector (3 and 4 contacts) and mA input connector
(1 (-) and 2 (+) contacts ).
Connect the suction tube (PVC soft cristal) to the foot filter that is supplied, having care to
insert in the hose, first the nut then the hose guard and finally the hose connection , this last
one inside the hose until the end. Screw the nut and put the foot filter into the liquid suction
lift tank. The level probe (optional) has to be connected to the filter through the support that
is supplied.
Cod. 00.009.307
In the figure: filter, level probe and PVC Cristal
suction hose.