LIVARNO HOME LSLB 100 A2
Remove the 4 screws and take off the cover of
the terminal box (7).
1. Release the power cable fitting (8) by turning
anticlockwise, using a suitable open-jawed
spanner if required.
2. Remove the power cable fitting (8) and the
seal underneath it (arrow). Note: Pay attention
to the correct installation position of this seal for
when you put it back together later.
Note: For the electrical installation, please use
an installation cable with a diameter of at least
8.2 mm, e.g. NYM-J 3x1.5mm², to ensure
sealing at the cable entry.