Connecting the inverter
• The air intake on the underside or the air outlet on the back side of the inverter
must remain clear.
• For ambient temperatures higher than 40 °C (such as in engine or heating com-
partments, or direct sunlight), the heat from the inverter under load can lead to
the automatic shut-off of the inverter.
• The installation surface must be level and sufficiently strong.
A
NOTICE!
Before drilling any holes, ensure that no electrical cables or other parts
of the vehicle can be damaged by drilling, sawing and filing.
Fasten the inverter as follows (fig. 3, page 4):
➤ Clip two holders on the lower left bar and two on the right.
You can move the holders as required.
➤ Fasten the inverter by screwing one screw through each hole in the holders.
7
Connecting the inverter
A
NOTICE!
The cable between the battery and the inverter may not exceed a
maximum length of 2 m.
7.1
Connecting the MSI212 and MSI224
The connection is made via a plug that is connected to a 12 V vehicle socket (for
MSI 212) and a 24 V vehicle socket (for MSI224) (fig. 6, page 5).
➤ Connect the middle pin (1) of the plug to the positive wire.
➤ Connect the two side brackets (2) of the plug to the negative wire.
A
NOTICE!
• Make sure that the plug is firmly connected in the vehicle socket. If
the connection is loose, the plug may heat up.
• The rating of the vehicle socket, the supply cable, and the fuse must
be at least 15 A. Do not put in a fuse with a higher rating.