4 Taking into service
Consult the separate manual for hydraulic pumps for instruc-
tions concerning taking the whole system into service.
Remove the filler cap and
filter from the hydraulic
tank.
Fill the hydraulic tank with
hydraulic oil. Only use an
oil specified in the techni-
cal details.
The tank capacity is 60
litres.
Replace the filter and tight-
en the filler cap by hand.
A combined thermometer/
depth gauge is fitted to
the tank.
The depth gauge must
show 2/3 full of oil when
the installation is in serv-
ice.
Depending on the total
length of the hoses, the
oil level may be above the
gauge before putting into
operation.
The five-fold base plate
comes complete with con-
nection. The manometer
can be connected to this.
'Power Hydraulics', Hydraulic installation
HTM0081
HTM0082
HTM0131
5 Maintenance
- Regularly check that all connections are tight.
- Return filter
The filter element must be
replaced once a year.
Art. code: HT5146
6 Technical data
Hydraulic fluid
Hydraulic oil
: in accordance with ISO VG 46
Viscosity
: 46 cSt at 40˚C
Viscosity index
: more than 100
Solidifying point
: below -27˚C
The following hydraulic oils satisfy the above specifications:
Vetus
: Hydraulic fluid ISO VG 46
Shell
: Tellus 46
Esso
: Nuto H46
Texaco
: Rando oil HD46
BP
: HLP46
ENGLISH
11