Complete Installation (Natural Gas to Propane
Gas)
1. Refer to the "Make Gas Connection" section for properly
connecting the range to the gas supply.
2. Refer to the "Electronic Ignition System" section for proper
burner ignition, operation and burner flame adjustments.
IMPORTANT: You may have to adjust the "LO" setting for
each cooktop burner.
Checking for proper cooktop, bake burner flame is very
important. The small inner cone should have a very distinct
blue flame 1/4" (0.64 cm) to 1/2" (1.3 cm) long. The outer cone
is not as distinct as the inner cone. Propane gas flames have
a slightly yellow tip.
3. Refer to "Complete Installation" in the "Installation
Instructions" section of this manual to complete this
procedure.
NOTE: Make sure to save the orifices that have just been
replaced in the conversion.
Natural Gas Conversion
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death or
serious burns to children and adults.
1. Turn manual shutoff valve to the closed position.
A.
To range
B.
Manual shut-off valve closed position
C.
Gas supply line
2. Unplug range or disconnect power.
To Convert Gas Pressure Regulator (Propane Gas
to Natural Gas)
1. Remove the storage drawer. See the Storage Drawer section.
2. Locate gas pressure regulator at rear of the drawer
compartment.
IMPORTANT: Do not remove the gas pressure regulator.
3. Remove plastic cover from gas pressure regulator cap.
4. Turn gas pressure regulator cap counterclockwise with a 5/8"
(1.6 cm) combination wrench to remove.
NOTE: Do not remove the spring beneath the cap.
A.
Plastic cover
B.
Gas pressure regulator cap with hollow end facing
out
C.
Gas pressure regulator cap with solid end facing out
D.
Washer
E.
Gas pressure regulator cap
5. Turn over the gas pressure regulator cap and reinstall on
regulator so that the solid end faces out and the marking
"↓NG" is facing the direction shown in the above drawing.
6. Replace plastic cover over gas pressure regulator cap.
To Convert Surface Burners (Propane Gas to
Natural Gas)
1. Remove burner cap.
2. Remove the burner base.
A.
Burner cap
B.
Burner base
C.
Alignment pins
D.
Igniter electrode
E.
Gas tube opening
A.
Burner cap
B.
Burner base
A
B
Large Burner
23