Télécharger Imprimer la page

HomeMatic IP HmIP-FALMOT-C12 Notice D'installation Et D'emploi page 29

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 43
Start-up
• Use a pen to mark the positions of
the two bore holes with a distance
of 120 mm on the wall.
Figure 3
• Use an appropriate drill to make
the 6 mm holes as illustrated.
• Fasten the screws and plugs sup-
plied to mount the floor heating
controller.
6.2
DIN rail mounting
To mount the floor heating controller
to a DIN rail, proceed as follows:
• Position the floor heating control-
ler on the DIN rail.
• Press the latching lugs (G) upwards
to lock the floor heating controller.
Figure 4
• Make sure that the latching lugs
are completely latched and that
the device is seated securely on the
rail.
7
Start-up
7.1
Installation instructions
Please read this entire section
before starting the pairing proce-
dure.
For installing the floor heating
controller into a power distribu-
tion panel, it must be installed in
accordance with VDE 0603, DIN
43871 (low-voltage sub-distribu-
tion board), DIN 18015-x. In this
case, installation must take place
on a mounting rail (DIN rail) ac-
cording to EN 50022. Installation
and wiring must be performed
according to VDE 0100 (VDE
0100-410, VDE 0100-510 etc.).
Please consider the technical con-
nection requirements (TCRs) of
your energy supplier.
Please observe the hazard infor-
mation in section
information" on page 25)
ing installation.
Permitted cable cross-sections for
the cable bushings of the floor heating
controller are:
Cable bushings
1 (K)
2 (L)
3 (M)
4 (N)
(see figure)
(see „3 Hazard
dur-
Cable
cross-section
[mm2]
> 8.0
> 5.5
> 3.6
> 4.4
29