Overview
1 Adapter
2 Coupling nut
3 Rotating triangular brush
Description of functions
Please refer to the descriptions below for
information on how the operating elements
work.
Technical data
Rotating
triangular brush ...........PRDB 21 A1
Maximum working/rated pressure
(P max) ...................... 15 MPa / 150 bar
Permissible pressure
(P max) ...................... 18 MPa / 180 bar
Flow rate (Q max) .......................450 l/h
Inlet temperature (T max) .................60 °C
Adapter
Suitable for pressure washers with the
following performance data:
Maximum working/rated pressure
(P max) ...................... 15 MPa / 150 bar
Permissible pressure
(P max) ...................... 18 MPa / 180 bar
Flow rate (Q max) .......................450 l/h
Inlet temperature (T max) .................60 °C
Safety information
• Pay attention to the sensitivity of the
surface when choosing the pressure
washer accessory.
• To prevent damage, please also note
the manufacturer's instructions for the
object being cleaned.
• Pay attention at all times. Pay
attention to what you are doing and go
about your work with common sense.
• Avoid abnormal body postures.
Ensure secure footing and keep your
balance at all times.
• Keep your work area tidy.
An untidy workplace can lead to acci-
dents.
• Wear suitable work clothing.
- When working outdoors, non-slip
footwear is recommended.
- Wear a hair net to contain long hair.
• Consider environment influences.
Make sure the workplace is well lit.
• Use only original accessories and do
not carry out any modifications.
Symbols on the product
Attention!
Read the instruction manual
Do not reach under the pressure
washer attachment during operation.
Wear safety goggles or a safety
mask
Operation
Connecting the pressure
washer attachment
Connecting without adapter
1. Connect the accessory to your Parkside
pressure washer via the high-pressure
connection by inserting, pressing and
turning (bayonet lock).
2. Fix the connection by tightening the
coupling nut (2).
Connecting with adapter
1. Connect the adapter (1) to the access-
ory by inserting, pressing and turning
(bayonet catch).
2. Fix the connection by tightening the
GB
MT
9