EVENT
Dip 1 ON (hold-to-run mode)
Or failure of a safety device
Dip 2 ON (full stroke programming)
Dip 2>1 ON (pedestrian stroke programming)
Programming sequence stopped due to intervention of a safety device
EVENT
No transmitter code entered
Dip 1 > 2 - transmitter code programming for full opening
Dip 1 > 3 - transmitter code programming for pedestrian opening
Correct transmitter codes programming for full opening
Correct transmitter codes programming for pedestrian opening
Remote control code not present in memory
Memory saturated by remote control codes (1000 codes saved)
Radio code deletion for full opening, pedestrian opening
EVENT
Stop button pressed
Photocell intervention
Edge intervention
Failure of a safety device or safety device engaged for too long
Alarm from edge
Failed photocells auto-test alarm
Functional block activated by smartphone
Achievement of set cycles
Energy saving activated by smartphone
Alarm from Self-learning failed
FAULT
After having carried out the various connections and having
supplied voltage, all the LEDS are switched off.
The gate opens but does not close after the time set.
The gate does not open or close by activating the various
START, RADIO, OPEN and CLOSE buttons.
By activating the START, OPEN or CLOSE button the gate does
not move.
Safety occurred during the slow speed phase and the gate
reversed the movement at slow speed, stopping before
completing the opening.
When the gate is completely closed and the closure limit switch
is pressed, giving the opening command the operator does not
start at high speed.
Now that you have finished the system, you want the gate to be
faster than how it was set.
All manuals and user guides at all-guides.com
TABLE SUMMARISING VISUAL AND SOUND ALARMS
SIGNALS DURING PROGRAMMING SEQUENCE
BUZZER STATUS
10 seconds tone with 2 seconds pause
BUZZER STATUS
WARNING SIGNALS DURING OPERATION
BUZZER STATUS
2 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
4 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
6 Tones every 5 seconds
(It is renewed by giving a command)
Continuous tone for 10 seconds with
2-second pause.
Not active when DIP 2 in OFF
On the board there are resettable fuses which intervene in the event of a short circuit, interrupting the output
assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable connectors and insert them one
at a time in order to more easily identify the cause of the fault.
Check the integrity of fuse F1.
In case of interrupted fuse use only of adequate value
F1 = T 5A Fuse for motor protection
Make sure that the TCA trimmer is activated with LED DL11 ON.
B.I.O. contact always on / green led on => check the status of the clock connected to B.I.O. input.
Photocells Auto-test failed => check the connections between the control panel and the photocells.
Faulty safety edge contact. Faulty photocells contact with DIP 4 OFF. => Fix or replace the faulty contact.
Photocells Auto-test failed => check the connections between the control panel and the photocells.
START, OPEN or CLOSE command always active.
Check and replace any buttons or micro-switches of the selector switch.
It's normal. Press the CLOSE command. The gate will close at slow speed. Once the close limit switch has been pressed,
by giving an opening command the operator will start at high speed.
Alert pedestrians not to transit during gate movement, especially while close to completing the closing movement. IT'S
VERY DANGEROUS!
1 ° IMMEDIATELY CUT OFF THE POWER SUPPLY !
The inverter box has been opened without authorization and the microswitches SW1 and SW2 have been set to ON.
Reposition them in OFF.
If an antenna wire is connected to the cover and you do not know how to reconnect it properly, remove it to avoid creating
a short circuit by closing the cover.
DO NOT LEAVE SCORES OR METAL DEPOSITS OF ANY KIND ON THE ELECTRONIC CIRCUIT.
2nd: If giving a command to the engine you do not hear the electrobrake being released, then the brake magnet is
damaged. Giving continuous commands will burn the inverter because it will be subjected to continuous voltage peaks that
will overheat it too much.
Order a brake magnet replacement. In the meantime, unlock the operator and operate the gate manually.
Send your request to ribind@ribind.it attaching photographs of the door, its weight, the speed you want. You will be
contacted as soon as possible.
BY REMOVING THE INVERTER COVER YOU WILL NOT HAVE ACCESS TO ANY DEVICE THAT WILL MAKE YOU VARYING THE
OPERATOR'S SPEED. YOU WILL ONLY INVALIDATE THE WARRANTY.
35
FLASHER STATUS
Off
Off
Off
Off
Off
Off
Off
FLASHER STATUS
Off
Off
Off
Off
Off
Off
1 Tone
Off
1 Tone
Off
Off
Off
Off
Off
2 Tones
Off
FLASHER STATUS
Off
Off
1 Tone
Off
2 Tones
Off
Off
Off
Enabled for 1 minute
Off
Off
Off
Off
Off
Off
Off
SOLUTION
DL1 LED STATUS
Flashes on-off 250 ms
Flashes on-off 500 ms
Flashes on-off 500 ms
On steady
DL12 LED STATUS
Flashes intermittently red/green
Flashes red for 10 seconds
Flashes green for 10 seconds
Turns green once
Turns red once
Turns red once
Runs 6 green flashes
Runs 2 green flashes
LED STATUS AND SIGNAL OUTPUT
Led DL6 turns off
Led DL7-8 turns off
Led DL9-10 turns off
Led DL1 flashes on-off 250 ms
No led combined
No led combined
Led DL12 is steady on green.
No leds matched
Blue led flashes once every 5 seconds
No leds matched
G
B