Warning indicators and remedies
Indicator status
(Lights
(Flashes
in red)
in red)
18
GB
Indicators
The number of
Meaning
flashes
Twice
The rear panel, side
cover, or air filter is
not installed
securely.
Three times
The lamp does not
light properly.
Eight times
The lens is not
securely attached.
Nine times
The projector is
installed at the wrong
angle.
Remedies
Check how the rear panel,
side cover, and air filter are
attached and install securely.
The temperature of the lamp
is unusually high. Turn off
the projector and turn it on
again after the lamp has
cooled. If the same symptom
occurs, turn off the projector
again and remove the lamp
(page 20), then check if the
lamp is not broken.
If the lamp is not broken,
reattach the lamp and turn on
the projector again.
If the symptom occurs again,
the lamp may be exhausted.
In this case, replace the lamp
with a new one (page 20).
If the lamp is broken, do not
exchange the lamp by
yourself. Consult a qualified
Sony consultant.
Check how the lens is
attached and install it
securely.
• Refer to "On Installation"
in Quick Reference
Manual and install at a
correct angle.