ATTENTION
Improperly performed repairs may result in personal injury or damage to the device.
8.2 Troubleshooting table
Error
Device does not
turn on.
A complete vacu-
um is not being
created in the bag.
The bag is not
being welded
correctly.
The bag does not
hold the vacuum
after it has been
sealed.
Bag is melting.
PLEASE NOTE
If you cannot solve the problem by carrying out the steps described above, our Cus-
tomer Service will help you free of charge.
9
Disposal of the Old Device
To protect the environment, it's important to dispose of old electronic devices
properly. Do not place your old unit in the non-recyclable waste under any
circumstances.
Possible cause
Power plug is not plugged in.
Defective power cord.
Defect socket outlet.
The open end of the bag is not
completely inside the vacuum
chamber.
The bag is defect.
There is dirt on the welding
and the normal seals.
The sealing bar is overheating
so that the bag melts.
Defect sealing bar.
The bag is defective.
There are leaks along the
welding seam as a result of
creases, crumbs, grease or
liquids.
The bag was sealed too long.
Rectifi cation
Plug in the power plug.
Send device to Customer
Service.
Select other outlet.
Position the bag correctly.
Select another bag.
Clean the seals and retry cor-
rectly once they are dry.
Open the cover on the unit
and let it cool down for a few
minutes.
Replace the sealing bar.
Select another bag; wrap paper
around any sharp edges within
the bag.
Open the bag again and clean
the upper internal part of
the bag. Remove any foreign
matter that might be on the
welding bar before sealing.
Check if the sealing time is too
long.