TILTING HAND
Receivers have the ability to control an output proportionally (accelerometer):
upon pressing a key and with the handheld in the horizontal starting
position, the proportional solenoid valve is activated at the minimum value.
To increase/decrease the speed, simply tilt the handheld to the left/right by
rotating the wrist and keeping the selected key pressed. As the inclination
increases, the speed of movement increases.
SLOWS
STARTING POSITION
ACCELERATES
> In the event of inactivity, the system automatically exits calibration mode after 30 seconds, without changing the current settings.
> Leaving the handheld tilting range, the YELLOW LED flashes indicating that it is above the MIN or MAX value that can be calibrated.
> For easier calibration, it is preferable to first set the MAX value and then the MIN value.
> The system is supplied with default proportional solenoid valve values
CALIBRATION OF THE PROPORTIONAL VALVE
The calibration procedure allows you to set the MINIMUM and MAXIMUM
movement speeds by storing them in the SMARTBOX.
1. With the system is switched on, press START and STOP on the handheld
simultaneously for at least 2 seconds until the RED LED on the handheld
lights up: the system is now in calibration mode.
2. To set the MAX value, press START and the key corresponding to the
desired function at the same time, with the handheld device level to
the ground. Keeping the keys pressed, tilt the handheld left or right (by
rotating the wrist). Once the desired value has been reached, release the
keys. The MAX value cannot be less than the MIN value.
3. To set the MIN value, press the key corresponding to the desired function
SLOWS
with the handheld level to the ground.
Keeping the key pressed, tilt the handheld left or right (by rotating the
wrist). Once the desired value is reached, release the key. The MIN value
cannot be greater than the MAX value.
4. Repeat steps 2 and 3 for all desired commands.
5. To exit calibration mode, press STOP and make sure the RED LED turns off.
6. It is now possible to activate the functions with the proportional solenoid
ACCELERATES
valve calibrated to the saved values.
85