en
3 Installation
3.2.4
Connecting the pump
Fig.7
Pump connector
B
N L
3.2.5
Connecting a room thermostat
Fig.8
R-Bus connector
C
B
PWM
R-Bus
3.2.6
Connecting an external flow temperature sensor
Fig.9
Tflow connector
C
B
Tflow
Tflow
3.2.7
Connecting a solar collector temperature sensor
Fig.10
T Coll T2 connector
T Coll
T2
6
The pump connector can be used to connect a zone pump.
Connect the pump as follows:
Earth
N
Neutral
L
Phase
AD-3002122-01
The R-Bus connectors can be used to connect a room thermostat. The B
connector is used for circuit B and the C connector is used for circuit C.
The connectors support the following types of thermostats:
R-Bus thermostat.
OpenTherm thermostat.
OpenTherm Smart Power thermostat
On/off thermostat
AD-3002123-01
It does not matter which wire is connected to which cable clamp. The
software recognizes which type of thermostat is connected.
The B / PWM connector doubles as a solar pump connector.
The Tflow connector can be used to connect a flow temperature sensor for
use in the system.
AD-3002125-01
The T Coll T2 connector can be used to connect the solar collector
temperature sensor.
AD-3002124-01
7801273 - 1 - 29062022