Tab.16
Optional parameters
Parameter
SP287
Solar hydraulic type
SP362
Heat dump type
SP010
Solar operating mode
SP011
Solar sensor type
SP058
Tmin tank charge
SP051
Tanks recooling
SP059
Solar collector mode
SP000
Tmax heat medium
SP021
Toffset evaparation
SP034
Tmax solar collector
SP322
Toffset extra tank
7801273 - 1 - 29062022
Description
Menu path
Selects the solar hy
draulic installation type.
> Solar Systems > In
stallation Type
Selects the type of heat
dump that is used when
> Solar Systems > In
the solar collector(s)
stallation Type
and solar tank(s) have
reached the maximum
temperature. This can
be a radiator or a fan
coil (or ventilator).
Selects the operating
mode for the solar. This
> Solar Systems > In
determines where the
stallation Type
solar heat will be stor
ed.
Selects the solar collec
tor sensor type.
> Solar Systems > In
stallation Type
Sets the minimum solar
collector temperature
> Solar Systems > In
before solar energy will
stallation Type
be charged into either
the DHW or CH solar
tanks.
Select the recooling
mode which must be
> Solar Systems > In
used for the DHW and
stallation Type
CH solar tanks.
Select the operating
mode for the solar tube
> Solar Systems > In
collector function.
stallation Type
Sets the maximum al
lowed temperature for
> Solar Systems > Pro
the heat conducting
tection
medium in order to pro
tect the pump.
Sets the offset evapora
tion temperature of the
> Solar Systems > Pro
solar collector. It is
tection
used to calculate if the
solar pump can be put
safely to ON again.
Sets the maximum al
lowed temperature in
> Solar Systems > Pro
the solar panel for over
tection
heat protection.
Sets the offset temper
ature of the additional
> Solar Systems > Pro
solar storage tank.
tection
Options
0 No solar
> Installation Setup
1 1layered tank-1valve
2 1 tank - 1 pump
3 2 tanks-1 valve
4 East/West - 1 tank
5 2 tanks-2 pumps
6 2 tanks-1 heat exch
0 None
> Installation Setup
1 Radiator
2 Fan coil
0 Off
> Installation Setup
1 DHW
2 CH
3 DHW + CH
0 NTC sensor
> Installation Setup
1 PT1000 sensor
2 PT100 sensor
8 - 90 °C
> Installation Setup
0 Off
> Installation Setup
1 Nightly
2 Summer
3 Temperature
0 Off
> Installation Setup
1 Time
2 On
60 200 °C
> Installation Setup
5 40 °C
> Installation Setup
60 200 °C
> Installation Setup
5 40 °C
> Installation Setup
en
3 Installation
Factory setting
0 No solar
0 None
3 DHW + CH
0 NTC sensor
30 °C
3 Temperature
2 On
120 °C
5
100
5
15