4 Settings
4.4
DHW Solar settings
Tab.22
Factory settings at installer level
Code
Display text
SP000
Tmax heat medi­
um
SP010
Solar operating
mode
SP011
Solar sensor type Selecting the solar collector sensor
SP021
Toffset evapara­
tion
SP031
Tmin solar collec­
tor
SP032
Frost protect hyst Frost protection hysteresis tempera­
SP033
Antifreeze agent
%
SP034
Tmax solar col­
lector
SP044
Tsetp DHW
charge
SP045
Tsetp max DHW
charge
SP046
Tsetp DHW limit
SP047
Tsetp nom CH
charge
SP048
Tsetp max CH
charge
SP049
Tsetp CH limit
SP050
Tank charge prio
SP051
Tanks recooling
SP052
Tmax recooling
mode
SP053
Recooling time
delay
SP054
Recooling mode
time
SP055
DHW recooling
temp
SP056
CH recooling
temp
SP057
Tank recool prio
22
Description
Maximum solar pump temperature for
heat conducting medium
Selecting the operating mode for the
solar
type
Offset evaporation temperature of the
solar collector
Minimum temperature in solar collec­
tor to prevent the heat conducting
medium from freezing
ture of solar collector
Percentage of antifreeze agent in the
heat conducting medium
Maximum temperature allowed for
solar collector
The setpoint temperature for DHW
cylinder charge
Setpoint maximum temperature for
DHW cylinder charge
The setpoint for DHW cylinder limit
temperature
Setpoint nominal temperature for CH
tank charge
Setpoint maximum temperature for
CH tank charge
The setpoint for CH tank limit temper­
ature
Tank charge priority for storing solar
energy
The recooling mode for the DHW and
CH solar tanks
Maximum temperature for solar col­
lector in recooling mode
Time delay during which the solar
collector temperature can be below
its maximum (SP052)
The recooling mode time for DHW
and CH solar tanks
DHW solar cylinder target tempera­
ture when the solar collector is in re­
cooling mode
CH solar tank target temperature
when the solar collector is in recool­
ing mode
Tank priority for solar collector recool­
ing mode
Adjustment range
60 - 200 °C
0 = Off
1 = DHW
2 = CH
3 = DHW + CH
0 = NTC sensor
1 = PT1000 sensor
2 = PT100 sensor
5 - 40 °C
-20 - 5 °C
5 - 40 °C
0 - 60 %
60 - 200 °C
8 - 60 °C
8 - 90 °C
40 - 95 °C
8 - 60 °C
8 - 90 °C
40 - 95 °C
0 = CH
1 = DHW
0 = Off
1 = Nightly
2 = Summer
3 = Temperature
8 - 90 °C
0 - 60 Min
0 - 240 Min
8 - 90 °C
8 - 90 °C
0 = CH
1 = DHW
Submenu
Default
setting
Solar sys­
120 °C
tems
Solar sys­
Off
tems
Solar sys­
PT1000
tems
sensor
Solar sys­
5 °C
tems
Solar sys­
0 °C
tems
Solar sys­
5 °C
tems
Solar sys­
0 %
tems
Solar sys­
100 °C
tems
Solar sys­
60 °C
tems
Solar sys­
80 °C
tems
Solar sys­
95 °C
tems
Solar sys­
60 °C
tems
Solar sys­
80 °C
tems
Solar sys­
95 °C
tems
Solar sys­
DHW
tems
Solar sys­
Tem­
tems
pera­
ture
Solar sys­
70 °C
tems
Solar sys­
40 Min
tems
Solar sys­
120 Min
tems
Solar sys­
70 °C
tems
Solar sys­
70 °C
tems
Solar sys­
CH
tems