PRESENCE DETECTOR
11 - 12
TESTS
Terminals
Input/Output
INSIDE SENSOR (N.O.)
13 - 17
(17= Common)
OUTSIDE SENSOR
14 - 17
(N.O.)
(17= Common)
PHOTOCELLS
15 - 17
1
PAIR (N.C.)
st
(17= Common)
FOTOCELLULA 2 (N.C.)
16 - 17
(17= Common)
CONNECTOR J16:
Terminals
Input/Output
EMERGENCY
18 - 20
(N.C.)
(20= Common)
CLOSE/LATCHING
RELAY
19 - 20
(N.O.)
DIP # 7 on SW1 on OFF
(20= Common)
CLOSE/LATCHING
RELAY
19 - 20
(N.O.)
DIP # 7 on SW1 on
ON(20= Common)
11= 24V DC TEST
12= - TEST
Door StatusFunction
Closed
Opens in "EXIT ONLY" and "AUTO".
Opening
None.
Reverts motion and opens in "EXIT ONLY" and
Closing
"AUTO".
Open
Door won't close until sensor is released.
In pause
None.
Closed
Opens in "ENTRY ONLY" and "AUTO".
Opening
None.
Reverts motion and opens in "EXIT ONLY" and
Closing
"AUTO".
Open
Door won't close until sensor is released.
In pause
None.
Closed
None.
Opening
None.
Closing
Reverts motion and opens.
Open
Door won't close until photocells are released.
In pause
None.
Closed
None.
Opening
None.
Closing
Reverts motion and opens.
Open
Door won't close until photocells are released.
In pause
None.
Door Status Function
Opens in any program, except in "LOCKED". When
Closed
dip # 1 on SW1 is set on ON opens also in "LOCKED".
Opening
None.
Closing
Reverts motion and opens.
Open
Door won't close until input is released.
In pause
None.
Closed
None.
Opening
Reverts motion and opens.
Closing
None.
Open
Closes in any program, except in "HOLD OPEN".
In pause
None.
Closed
Opens in any program, except in "LOCK".
Opening
Reverts motion and closes, except in "HOLD OPEN".
Closing
Reverts motion and opens, except in "LOCK".
Closes in any program, except in "HOLD OPEN".
Open
IMPORTANT: Auto Close function is disabled.
In pause
Closes.
22