Télécharger Imprimer la page

tau DC19 Notice D'installation page 20

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
CONTROL PANEL FOR SLIDING DOOR OPENERS
MICROPROCESSOR-BASED CONTROLLER
LED INPUT STATUS INDICATORS
ENCODER SENSOR FOR SELF-LEARNING OF TRAVEL
BATTERY CHARGER BOARD (INTEGRATED)
BATTERY CONNECTOR
DIAGNOSTICS LEDS
ATTENTION:
-
do not use single cables (with one single wire), ex. telephone cables, in order to avoid break-
downs of the line and false contacts;
-
do not re-use old pre-existing cables;
TESTING
Once the connection is completed:
The green LEDs must all be lit (they correspond to a Normally Closed input each). They switch
off only when the controls they are associated to are involved.
The red LEDs must all be off (they correspond to a Normally Open input each); they light only
when the controls they are associated to are involved.
TECHNICAL CHARACTERISTICS
Board power supply
Max motor power DC
Fast acting fuse entrance 230V AC (F5 - 5x20)
Fast acting fuse for protection of auxiliary circuits 24 V CC (F1 -
5x20)
Fast acting fuse for motor protection 40Vcc (F2 - 5x20)
Motor power supply circuits voltage
Auxiliary device circuits supply voltage
Logic circuits supply voltages
Operating temperature
WORKING PROGRAMS
Six different working programs can be selected (can be set by mechanical selector or by TLINETD
programmer):
"SOLO ENTRATA" (ENTRY ONLY)
"SOLO USCITA" (EXIT ONLY)
"ENTRAMBI I SENSI" (AUTO)
"SEMPRE APERTA" (HOLD OPEN)
"BLOCCATA CHIUSA" (LOCK)
"APERTURA INVERNALE" (WINTER OPENING)
"APERTURA FARMACIA" (PHARMACY OPENING) (only through the TLINETD device)
Program
"SOLO ENTRATA"
(ENTRY ONLY)
Description
Entering Traffic
Active inputs
Outside Radar
Close (Latching Relay)
Emergency
20
20V+40V AC - 50 Hz
100 W - 40 V DC
3.15A
2 A
6,3 A
40 V DC
24 V DC
5 V DC
-20 °C ÷ +55 °C
Remarks

Publicité